首页 | 本学科首页   官方微博 | 高级检索  
     

串联感应加热电源相角保护
引用本文:田维,嵇启春.串联感应加热电源相角保护[J].工业控制计算机,2014(5):150-151.
作者姓名:田维  嵇启春
作者单位:西安建筑科技大学信息与控制工程学院,陕西西安710055
摘    要:数字感应加热电源在工业中一般采用串联负载与PFM调功方式。串联负载谐振与PFM调功方式要求逆变器频率稳定工作在感性区,但在实际工作过程中逆变器频率可能会由感性区越过谐振点滑入容性区,引起逆变器发生"炸管"现象。为了防止"炸管"现象的发生,在谐振点附近的感性区设置限相区,当频率进入限相区经PI处理使其稳定工作在感性区达到保护逆变器的目的。通过DSP实验平台测试,限相区的设置可以很好的保护逆变器使其稳定工作在感性区。

关 键 词:感应加热电源  PFM  限相区  容性区

Series Resonant Induction Heating Power Supply Phase Angle Protection
Abstract:In industry,digital induction heating power using serial load resonant and regulation of power by PFM.Serial load resonant and PFM requirements inverter frequency stability work in inductive region,but at work the inverter frequency will slip resonance frequency enter into the capacitive region,in which the inverter will caused explode.In order to prevent the explode phenomenon occurred in the near resonance frequency set a limit phase region,when the frequency entered into the limit phase region by PI it will stability work in the inductive region.
Keywords:induction heating power  PFM  limited phase  capacitive region
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号