首页 | 本学科首页   官方微博 | 高级检索  
     

基于MSC Nastran的高压接线箱静强度分析
引用本文:徐聪.基于MSC Nastran的高压接线箱静强度分析[J].计算机辅助工程,2013,22(Z1):435-438.
作者姓名:徐聪
作者单位:青岛理工大学 机械工程学院
摘    要:地铁用高压接线箱必须满足在复杂工况作用下的静强度要求.依据标准BS EN 12663 1:2010的要求,用MSC Nastran分析某地铁用高压接线箱静强度.分析结果表明该地铁用高压接线箱所用材料满足强度要求.

关 键 词:地铁    高压接线箱    静强度    有限元
收稿时间:2013/4/12 0:00:00

Static stength analysis on high voltage junction box structure based on MSC Nastran
XU Cong.Static stength analysis on high voltage junction box structure based on MSC Nastran[J].Computer Aided Engineering,2013,22(Z1):435-438.
Authors:XU Cong
Affiliation:School of Mechanical and Engineering, Qingdao Technology University
Abstract:The high voltage junction box for metro must meet the static strength requirements under complex conditions. According to the criterion BS EN 12663 1: 2010, the static stength of high voltage junction box structure is analyzed by MSC Nastran. The analysis results show that the material of the high voltage junction box meet the strength requirements.
Keywords:metro  high voltage junction box  static strength  finite element