首页 | 本学科首页   官方微博 | 高级检索  
     

混合干涉型分布式光纤天然气管道泄漏检测及定位方法研究
引用本文:章仁杰,杨其华,王强,胡正松.混合干涉型分布式光纤天然气管道泄漏检测及定位方法研究[J].中国计量学院学报,2013,24(2).
作者姓名:章仁杰  杨其华  王强  胡正松
作者单位:中国计量学院质量与安全工程学院,浙江杭州,310018
基金项目:质检行业公益性科研专项,浙江省杰出青年基金项目
摘    要:介绍了一种基于马赫-曾德尔和萨格纳克混合干涉仪原理的分布式光纤天然气管道泄漏检测系统.阐述了检测系统的检测原理及泄漏定位方法,在泄漏点距法拉第旋转镜为6 032m处进行了气体管道泄漏检测实验并重复做了20次试验,测试了传感光纤与泄漏点不同夹角对检测系统性能的影响.实验结果表明,该系统可以检测出管道内气体压力为0.3MPa、泄漏孔径为2.5mm的微小泄漏信号并进行定位,平均相对定位误差为1.29%.在40mm的管道外径下,传感光纤与泄漏点夹角在0~180°范围内,检测系统均能检测出泄漏信号并进行定位.

关 键 词:混合干涉仪  泄漏检测  定位方法  管道泄漏检测实验

Study on hybrid interference distributed fiber-optic natural gas pipeline leakage detection and location method
Zhang Renjie , Yang Qihua , Wang Qiang , Hu Zhengsong.Study on hybrid interference distributed fiber-optic natural gas pipeline leakage detection and location method[J].Journal of China Jiliang University,2013,24(2).
Authors:Zhang Renjie  Yang Qihua  Wang Qiang  Hu Zhengsong
Affiliation:Zhang Renjie Yang Qihua Wang Qiang Hu Zhengsong
Abstract:A distributed fiber-optic natural gas pipeline leakage detection system based on the hybrid interferometer principle of Mach-Zehnder and Sagnac was introduced.The detection principle and the leakage location method of the system are described.The experiment was carried out to detect the leakage point at 6 032 m from the Faraday rotator mirror,with 20 repetition.The influence of the angle between sensor fiber and the leakage hole on the detection system performance was tested.The experimental results show that the system is able to detect and locate the slight leakage signal of the gas pressure within the pipeline at 0.3 MPa,leakage aperture of 2.5 mm,with the average relative positioning error of 1.29%.The detection system can detect and locate the leakage signal of the pipeline diameter in 40 mm and the angle within the range of 0~180°.
Keywords:hybrid interferometer  leakage detection  location method  pipeline leakage detection experiment
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号