首页 | 本学科首页   官方微博 | 高级检索  
     

海水近表层光谱辐射计系统及其控制软件设计
引用本文:徐中民,禹秉熙,金锡峰,曹文熙,杨跃忠,柯天存,李彩.海水近表层光谱辐射计系统及其控制软件设计[J].测试技术学报,2004,18(4):283-287.
作者姓名:徐中民  禹秉熙  金锡峰  曹文熙  杨跃忠  柯天存  李彩
作者单位:1. 中国科学院,长春光学精密机械与物理研究所,应用光学国家重点实验室,吉林,长春,130033
2. 中国科学院南海海洋研究所LED实验室,广东,广州,510301
基金项目:国家863计划项目(2001AA631014)
摘    要:海洋光学浮标近表层光谱辐射计使用了8台PC2000-PC104型光纤光谱仪对海水4个层面8个通道进行光谱测量,本文介绍了光谱辐射计系统的组成、通信协议及PC2000-PC104型光纤光谱仪的光谱采集原理,特别是对于不正常的光谱采集结果进行了分析,提出了中断触发的4种可能情况,并对于光谱采集的异常现象作了解释,编写了完全封装的光谱仪数据采集类,解决了该问题。

关 键 词:PC104  光谱辐射计  中断  控制软件  系统  数据采集  通道  表层  海洋光学  海水
文章编号:1671-7449(2004)04-0283-05
修稿时间:2004年3月29日

Radiometric System for Measuring Spectrum Below Ocean Surface and the Design of Its Controlling Program
XU Zhong-min,YU Bing-xi,JIN Xi-feng,CAIO Wen-xi,YANG Yue-zhong,KE Tian-cun,LI Cai Fine Mechanics and Physics,Chinese Academy of Science,Changchun ,China, . South China Sea Institute of Oceanology,Chinese Academy of Science,Guangzhou ,China.Radiometric System for Measuring Spectrum Below Ocean Surface and the Design of Its Controlling Program[J].Journal of Test and Measurement Techol,2004,18(4):283-287.
Authors:XU Zhong-min  YU Bing-xi  JIN Xi-feng  CAIO Wen-xi  YANG Yue-zhong  KE Tian-cun  LI Cai Fine Mechanics and Physics  Chinese Academy of Science  Changchun  China  South China Sea Institute of Oceanology  Chinese Academy of Science  Guangzhou  China
Affiliation:XU Zhong-min~1,YU Bing-xi~1,JIN Xi-feng~1,CAIO Wen-xi~2,YANG Yue-zhong~2,KE Tian-cun~2,LI Cai~2 Fine Mechanics and Physics,Chinese Academy of Science,Changchun 130033,China, 2. South China Sea Institute of Oceanology,Chinese Academy of Science,Guangzhou 510301,China)
Abstract:Eight Ocean Optics PC2000-PC104 miniature fiber optic spectrometers are used in the ocean radiometric system to measure downwelling spectral irradiances and upwelling spectral radiances at four depths. In this paper the configuration of that system is introduced as well as the method of acquiring multi-channel data. Especially, the abnormal spectral data acquired from A/D card is analyzed. And it is found that there are four possibilities when the interrupt service routine (ISR) that read data from FIFO in the A/D card is running. It is the reason that leads to above abnormity. Finally, based on the OOP, the CADCard class that provides all the base functionality of the PC2000-PC104 spectrometer is built to implement multi-channel data acquisition readily using C++.
Keywords:spectrometer  multi-channel  communication protocol  interrupt  data acquisition  OOP
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏