预冷循环粗氩泵时突发故障的分析
引用本文:杨天明.预冷循环粗氩泵时突发故障的分析[J].深冷技术,2011(4):85-87.
作者姓名:杨天明
作者单位:首钢水城钢铁(集团)有限公司氧气厂;
摘    要:在准备切换6000 m3/h空分设备制氩系统循环粗氩泵时,由于预冷阀和进液阀开度过大,使运行泵发生汽蚀,运行效率降低,导致主塔工况波动。简介制氩系统的流程和主要技术参数,介绍故障发生时相关运行参数的变化情况和处理措施,阐述相应的防范措施。

关 键 词:空分设备  制氩系统  低温液体泵  切换  预冷

Analysis of trouble abruptly occurring at pre-cooling of circulation crude argon pump
Yang Tianming Co.,Ltd.,# Yejin Road,Baxi,Shuigang,Liupanshui ,Guizhou,P.R.China.Analysis of trouble abruptly occurring at pre-cooling of circulation crude argon pump[J].Cryogenic Technology,2011(4):85-87.
Authors:Yang Tianming Co  Ltd  # Yejin Road  Baxi  Shuigang  Liupanshui  Guizhou  PRChina
Affiliation:Yang Tianming(Oxygen Factory,Shougang Shuicheng Iron &Steel(Group) Co.,Ltd.,8# Yejin Road,Baxi,Shuigang,Liupanshui 553028,Guizhou,P.R.China)
Abstract:At switching over the circulation crude argon pump of argon generation system of 6000 m3/h air separation plant,excessive opening of the pre-cooling valve and the liquid inlet valve results in cavitation of the running pump,reduction of operation efficiency and fluctuation of working conditions of main tower.Here,the technical process and main technical parameters of the argon generation system are briefed,the change of related operation parameters at trouble and the corrective measures are described and th...
Keywords:Air separation plant  Argon generation system  Low-temperature liquid pump  Switching  Pre-cooling  