首页 | 本学科首页   官方微博 | 高级检索  
     

新型3列5级无水润滑氧压机带水原因探讨
引用本文:郑志明,汪铁平.新型3列5级无水润滑氧压机带水原因探讨[J].深冷技术,2008(1):58-61.
作者姓名:郑志明  汪铁平
作者单位:杭州杭氧压缩机有限公司,杭州市东新路388号310004
摘    要:介绍了新型3列5级无水润滑氧压机汽缸带水的故障现象,从氧气充装流程、氧压机运行方式和氧压机结构3方面进行了原因分析,最后提出了排除故障的措施。

关 键 词:氧压机  无水润滑  氧气充装  带水
收稿时间:2007-10-13

Cause analysis of the water entrainment in a novel 3-column 5-stage oxygen compressor with water-free lubrication
Zheng Zhi-ming,Wang Tie-ping.Cause analysis of the water entrainment in a novel 3-column 5-stage oxygen compressor with water-free lubrication[J].Cryogenic Technology,2008(1):58-61.
Authors:Zheng Zhi-ming  Wang Tie-ping
Abstract:Malfunction phenomenon of water entrainment in the cylinder of a novel 3-column 5-stage water-free lubricated oxygen compressor is described.The cause of the malfunction is analyzed from three aspects,i.e.oxygen-charging process,configuration,and operation mode of oxygen compressor.The measures of malfunction elimination are also proposed.
Keywords:Oxygen compressor  Water-free lubrication  Oxygen charging  Water entrainment