空压机冷却器冷却效果差引起排气压力超标的分析 |
| |
引用本文: | 郭明志.空压机冷却器冷却效果差引起排气压力超标的分析[J].深冷技术,2006(6). |
| |
作者姓名: | 郭明志 |
| |
作者单位: | 河南中原特殊钢集团有限公司动力公司137车间 河南省济源市 |
| |
摘 要: | 由于活塞式空压机二级冷却器冷却效果不佳,二级排气压力超过设计压力,造成安全阀起跳。更换二级冷却器,解决了此故障。介绍了保证活塞式空压机冷却器冷却效果的操作方法。
|
关 键 词: | 空压机 冷却器 排气压力 |
Analysis of overpressure at the exhaust due to cooler's poor performance in an air compressor |
| |
Abstract: | The second-stage exhaust pressure surpasses its design value, due to poor performance of the cooler in a reciprocating air compressor, which leads to action of safety valve. The replacement of second-stage cooler solves the problem. The measures to ensure the cooler's performance in a reciprocating air compressor are also presented. |
| |
Keywords: | Air compressor Cooler Exhaust pressure |
本文献已被 维普 等数据库收录! |