首页 | 本学科首页   官方微博 | 高级检索  
     

40000m~3/h空分设备上下塔压力背离现象的分析与处理
引用本文:卢子学,侯安祥.40000m~3/h空分设备上下塔压力背离现象的分析与处理[J].深冷技术,2006(6).
作者姓名:卢子学  侯安祥
作者单位:山东华鲁恒升化工股份有限公司 山东华鲁恒升化工股份有限公司 山东省德州市 山东省德州市
摘    要:介绍了一起40000m~3/h空分设备上下塔压力背离现象,经分析后确认是因为主冷氮侧液位过高,占据了换热空间;排放液氮并作相应调节后,故障消除。

关 键 词:大型空分设备  冷凝蒸发器  精馏塔压力

Analysis and treatment of pressure deviation in upper and lower columns of a 40000m~3/h air separation unit
Abstract:A case of pressure deviation in upper and lower columns of a 40000m~3/h air separation unit is introduced. Our analysis shows that the phenomenon is mainly caused by excessively high liquid level in nitrogen side of main cold heat exchanger, which occupies part of heat exchanging space. The malfunction was eliminated after liquid nitrogen was exhausted and corresponding adjustment was carried out.