首页 | 本学科首页   官方微博 | 高级检索  
     


Development of a light-weight portable neutron survey meter
Authors:Nunomiya Tomoya  Nakamura Takashi  Koyama Tetsuo  Inui Daisuke  Ishikura Takeshi
Affiliation:Fuji Electric Co, Ltd, 1 Fuji-machi, Hino-city 191-8502, Japan. nunomiya-tomoya@fujielectric.co.jp
Abstract:A light-weight portable neutron survey meter was developed using a mixed organic gas counter for dose management at nuclear power plants and accelerator facilities. This survey meter, NSN31041, is ~2 kg in weight and W160×H250×L300 mm(3) in size, which is capable of measuring neutron ambient dose equivalent rate from thermal to 15 MeV neutrons. The neutron energy response of the survey meter is evaluated using continuous energy neutron sources of (252)Cf, (241)Am-Be, thermal neutrons generated from a graphite pile loading a (252)Cf source, concrete-moderated neutrons of (241)Am-Be source and D(2)O-moderated neutrons of (252)Cf source. The measured response data show very good agreement with neutron ambient dose equivalent within a 50 % deviation.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏