首页 | 本学科首页   官方微博 | 高级检索  
     


Optimisation of internal contamination monitoring programme by integration of uncertainties
Authors:Davesne E  Casanova P  Chojnacki E  Paquet F  Blanchardon E
Affiliation:Internal Dosimetry Department, Institute for Radiological Protection and Nuclear Safety, IRSN/DRPH/SDI, BP 17, F-92262 Fontenay-aux-Roses Cedex, France.
Abstract:Potential internal contamination of workers is monitored by periodic bioassay measurements interpreted in terms of intake and committed effective dose by the use of biokinetic and dosimetric models. After a prospective evaluation of exposure at a workplace, a suitable monitoring programme can be defined by choosing adequate measurement techniques and frequency. In this study, the sensitivity of a programme is evaluated by the minimum intake and dose, which may be detected with a given level of confidence by taking into account uncertainties on exposure conditions and measurements. This is made for programme optimisation, which is performed by comparing the sensitivities of different alternative programmes. These methods were applied at the AREVA NC reprocessing plant and support the current monitoring programme as the best compromise between the cost of the measurements and the sensitivity of the programme.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号