Thermal conductivity andPVT measurements of pentafluoroethane (refrigerant HFC-125)
Authors:O B Tsvetkov  A V Kletski  Yu A Laptev  A J Asambaev  I A Zausaev
Affiliation:(1) Technological Institute of Refrigeration, 9 Lomonossov Street, 191002 St. Petersburg, Russia;(2) Institute of Food Technology, Semipalatinsk, Kazakhstan;(3) Institute of Food Technology, Kemerovo, Russia
Abstract:By means of the transient and steady-state coaxial cylinder methods, the thermal conductivity of pentafluoroethane was investigated at temperatures from 187 to 419 K and pressures from atmospheric to 6.0 MPa. The estimated uncertainty of the measured results is ±(2–3)%. The operation of the experimental apparatus was validated by measuring the thermal conductivity of R22 and R12. Determinations of the vapor pressure andPVT properties were carried out by a constant-volume apparatus for the temperature range 263 to 443 K, pressures up to 6 MPa, and densities from 36 to 516 kg m–3. The uncertainties in temperature, pressure, and density are less than ±10 mK, ±0.08%, and ±0.1%, respectively.Paper presented at the Twelfth Symposium on Thermophysical Properties, June 19–24, 1994, Boulder, Colorado, U.S.A.
Keywords:coaxial cylinders  constant-volume apparatus  pentafluoroethane  PVT properties  R125  refrigerant  thermal conductivity vapor pressure