首页 | 本学科首页   官方微博 | 高级检索  
     

锅炉一级再热器内壁腐蚀原因分析
引用本文:贺锡鹏,马红,张维科,曹海涛,唐丽英.锅炉一级再热器内壁腐蚀原因分析[J].理化检验(物理分册),2012(3):190-193.
作者姓名:贺锡鹏  马红  张维科  曹海涛  唐丽英
作者单位:西安热工研究院有限公司
摘    要:通过宏观和微观检验对型号为BP-1025的锅炉一级再热器内壁腐蚀原因进行了分析。结果表明:一级再热器管内壁腐蚀类型属于停用期问的氧腐蚀,是机组投运以来多次腐蚀累积的结果;泄漏管样的穿孔是以往形成的腐蚀坑,在此次停炉后再次腐蚀以致蚀穿管壁而造成的。

关 键 词:一级再热器  内壁腐蚀  氧腐蚀

Analysis on Corrosion Reason of First Reheater of Boiler
HE Xi-peng,MA Hong,ZHANG Wei-ke,CAO Hai-tao,TANG Li-ying.Analysis on Corrosion Reason of First Reheater of Boiler[J].Physical Testing and Chemical Analysis Part A:Physical Testing,2012(3):190-193.
Authors:HE Xi-peng  MA Hong  ZHANG Wei-ke  CAO Hai-tao  TANG Li-ying
Affiliation:(Thermal Power Research Institute,Xi’an 710032,China)
Abstract:The corrosion reason for inner wall of tube of first reheater of BP-1025 boiler has been analyzed by means of macro and micro examination.The results showed that the corrosion type was oxidation corrosion caused by shutdown of units;the first reheater corrosion can be attributed to the corrosion accumulation since the units was brought into operation.The hole through the tube on the leaky tube was result of continuous corrosion on previous formed corrosion pit.
Keywords:first reheater  inner wall corrosion  oxidation corrosion
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号