摘    要:通过实验,测试两器均采用φ7管径换热管的风冷冷风型单元机在不同冷凝器翅片密度情况下整机的制冷量及能效比值。根据实验测试数据,可直观评估冷凝器翅片密度的调整对整机性能的影响程度,为使用φ7管换热器的机型的全面开发提供重要的参数依据。

关 键 词:φ7管径换热管  冷凝器翅片密度  整机性能

Experiment Research on the Impact of Different Fin Destiny of Air - cooled Condenser in the Heat Exchange Tube of 7mm Diameter on the Performance of the Air- conditioning System
HUANG Haoliang,CHEN Hua,OU Yangti.Experiment Research on the Impact of Different Fin Destiny of Air - cooled Condenser in the Heat Exchange Tube of 7mm Diameter on the Performance of the Air- conditioning System[J].Refrigeration,2013(4):11-14.
Authors:HUANG Haoliang  CHEN Hua  OU Yangti
Affiliation:( Guangdong Shenling Air - conditioning Equipment Co. , Ltd. , Foshan, 528313 )
Abstract:Two air - cooled chillers with the heat exchange tube of 7mm are used to test the refrigerating capacity and energy efficiency with different fin destiny of air - cooled condenser. According to the test data, it is possible to estimate the extent of impact of the adjustment of fin destiny on the performance of the chiller so as to give reference to development of the chillers with the heat exchange tube of 7ram diameter.
Keywords:Heat exchange tube of 7mm diameter  Fin destiny of condenser  Performance of the air- conditioningsystem