首页 | 本学科首页   官方微博 | 高级检索  
     

CFRP薄壁C型柱轴向压缩破坏机制及吸能特性
引用本文:解江,张雪晗,宋山山,牟浩蕾,冯振宇.CFRP薄壁C型柱轴向压缩破坏机制及吸能特性[J].复合材料学报,2018,35(12):3261-3270.
作者姓名:解江  张雪晗  宋山山  牟浩蕾  冯振宇
作者单位:中国民航大学 民航民用航空器适航审定技术重点实验室, 天津 300300
摘    要:为研究碳纤维增强树脂基复合材料(CFRP)薄壁C型柱轴向压缩破坏机制及吸能特性,制备了4种铺层方式、3种厚度组合共12种T700/MTM28 CFRP薄壁C型柱试件。考察C型柱低速轴向压缩过程中的失效模式及载荷变化,通过比较初始峰值载荷、平均压缩载荷、比吸能和载荷效率,分析铺层数及铺层角度对C型柱失效模式及吸能特性的影响。结果表明,纯0°铺层C型柱在轴压载荷作用下发生整体失稳,不具备实际意义上的能量吸收作用;0°/90°铺层、±45°铺层、45°/90°/-45°/0°铺层试件均发生了渐进式破坏,呈现出局部屈曲叠缩的失效模式。其中,45°/90°/-45°/0°铺层的C型柱比吸能随铺层数的增加而增加,具有更大的吸能设计与应用潜力。

关 键 词:碳纤维增强树脂基复合材料(CFRP)  薄壁C型柱  铺层角度  失效模式  吸能特性  
收稿时间:2017-12-11

Failure mechanism and energy-absorbing characteristics of CFRP thin-walled C-channels subject to axial compression
XIE Jiang,ZHANG Xuehan,SONG Shanshan,MOU Haolei,FENG Zhenyu.Failure mechanism and energy-absorbing characteristics of CFRP thin-walled C-channels subject to axial compression[J].Acta Materiae Compositae Sinica,2018,35(12):3261-3270.
Authors:XIE Jiang  ZHANG Xuehan  SONG Shanshan  MOU Haolei  FENG Zhenyu
Affiliation:Key Laboratory of Civil Aircraft Airworthiness Technology, CAAC, Civil Aviation University of China, Tianjin 300300, China
Abstract:In order to analyze the failure mechanism and energy-absorbing characteristics of carbon fiber reinforced polymer(CFRP) thin-walled C-channels subject to axial compression, 12 groups of T700/MTM28 CFRP thin-walled C-channels specimens with 3 different layer numbers and 4 different ply orientations were fabricated. The failure modes and load-displacement curves were observed, then the effects of layer number and ply orientation on failure modes and energy-absorbing characteristics were further analyzed by investigating the energy-absorbing characteristics indicator, such as peak load, average load, specific energy absorption, load efficiency. The results show that for specimens with 0° plies, the overall instability occurs so it can not absorb crashing energy. For specimens with 0°/90°, ±45° and 45°/90°/-45°/0°plies, the steady progressive failure and local buckling failure modes are presented. The SEA of C-channel specimens with 45°/90°/-45°/0° plies increases with the layer number increasing and it hence has greater potential for energy-absorbing structure design and application.
Keywords:carbon fiber reinforced polymer (CFRP)  thin-walled C-channels  ply orientation  failure modes  energy-absorbing characteristics  
点击此处可从《复合材料学报》浏览原始摘要信息
点击此处可从《复合材料学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号