A New Hybrid Exponentially Weighted Moving Average Control Chart for Monitoring Process Mean |
| |
Authors: | Abdul Haq |
| |
Affiliation: | Department of Statistics, Quaid‐i‐Azam University, , Islamabad, 45320 Pakistan |
| |
Abstract: | Cumulative sum (CUSUM) and exponentially weighted moving average (EWMA) control charts are commonly used for monitoring the process mean. In this paper, a new hybrid EWMA (HEWMA) control chart is proposed by mixing two EWMA control charts. An interesting feature of the proposed control chart is that the traditional Shewhart and EWMA control charts are its special cases. Average run lengths are used to evaluate the performances of each of the control charts. It is worth mentioning that the proposed HEWMA control chart detects smaller shifts substantially quicker than the classical CUSUM, classical EWMA and mixed EWMA–CUSUM control charts. Copyright © 2012 John Wiley & Sons, Ltd. |
| |
Keywords: | process mean average run length control charts cumulative sum exponentially weighted moving average |
|
|