A 1-D analysis of ejector performanceAnalyse unidimensionnelle de la performance d'un éjecteur
Authors:B J Huang  J M Chang  C P Wang  V A Petrenko
Affiliation:Department of Mechanical Engineering, National Taiwan University, Taipei 106, Taiwan
Abstract:A 1-D analysis for the prediction of ejector performance at critical-mode operation is carried out in the present study. Constant-pressure mixing is assumed to occur inside the constant-area section of the ejector and the entrained flow at choking condition is analyzed. We also carried out an experiment using 11 ejectors and R141b as the working fluid to verify the analytical results. The test results are used to determine the coefficients, ηp, ηs, φp and φm defined in the 1-D model by matching the test data with the analytical results. It is shown that the1-D analysis using the empirical coefficients can accurately predict the performance of the ejectors.
Keywords:Refrigerating system  Ejector system  Refrigerant  R141b  Ejector  PerformanceAuthor Keywords: Systè  me frigorifique  Systè  me à  é  jecteur  Frigorigè  ne  R141b  É  jecteur  Performance