Experimental study of the refrigeration cycle performance for the R744/R290 mixtures |
| |
Authors: | Baolian Niu Yufeng Zhang |
| |
Affiliation: | aSchool of Environmental Science & Engineering, Tianjin University, Tianjin 300072, PR China |
| |
Abstract: | A new binary mixture of R744 and R290 as an alternative natural refrigerant to R13 was first presented in this paper. Its environmental performance is friendly. It has an ODP of zero and GWP smaller than 20. Experimental studies for this mixture and R13 were performed on a cascade refrigeration system only with modification to capillary in low-temperature circuit. COP and refrigeration capacity of this binary mixture were higher than those of R13, at the same time, condensing pressure, evaporating pressure, compression ratio, and discharge temperature were also higher than that of R13 when the high-temperature circuit of cascade refrigeration system was kept invariable. The new binary mixture of R744 and R290 is considered as a promising alternative refrigerant to R13 when the evaporator temperature is higher than 201 K. |
| |
Keywords: | Refrigerant Binary mixture Propane Carbon dioxide Replacement R13 Experiment Sorption Cascade Performance COPMots clé s: Frigorigè ne Mé lange binaire Propane Dioxyde de carbone Substitut R13 Expé rimentation Sorption Cascade Performance COP |
本文献已被 ScienceDirect 等数据库收录! |
|