首页 | 本学科首页   官方微博 | 高级检索  
     

浆滴参数对酸性烟气净化的影响分析
引用本文:臧仁德.浆滴参数对酸性烟气净化的影响分析[J].机床与液压,2017,45(6):47-55.
作者姓名:臧仁德
作者单位:重庆理工大学经济金融学院,重庆,400054
基金项目:supported by Xinghuo support plan for Youth scientific research of Chongqing University of Technology,project supported by key laboratory of low-grade energy utilization technologies and systems,ministry of education of China
摘    要:建立了SO2、HCl酸性烟气喷雾干燥净化的气相、颗粒相及传热传质数学模型,模拟了浆滴运行参数对酸性烟气净化的影响,研究了浆滴在塔内的位移随入口烟气速度的关系;实验分析了雾化加湿和浆滴浓度对烟气净化效率的影响.实验结果表明:喷雾干燥过程中加入雾化加湿水后,SO2、HCl的脱除效率都增加,SO2脱除效率增加明显;增加浆液浓度,SO2脱除率和HCl脱除率均略有下降,且SO2脱除率减小程度大于HCl.模拟结果表明:当入口烟气速度为5 m/s时,浆滴的位移范围较大;随着浆滴粒径的增加,浆滴的温度随着时间逐渐升高,30,60和9 0 μm粒径的浆滴温度分别在3,3,4 s时达到稳定;随着浆滴粒径的增加,脱除效率不断增加,30,60和90 μm粒径条件下 HCl的去除效率分别在1.5,1.7和2 s达到平衡,SO2的去除效率分别在2.5,3.5和4 s达到平衡,可以看出, HCl 与SO2相比,其达到最大脱除效率的时间更短;随着入口烟气温度升高,SO2和HCl的脱除效率都在增大,HCl脱除效率比SO2脱除效率达到稳定的时间更短.

关 键 词:浆滴  酸性气体  净化  脱除效率  喷雾干燥

The analysis of slurry droplets parameters' influence on the acid gas purification
Ren-de ZANG.The analysis of slurry droplets parameters' influence on the acid gas purification[J].Machine Tool & Hydraulics,2017,45(6):47-55.
Authors:Ren-de ZANG
Abstract:In this paper, the gas phase, particle phase and mathematical model of heat and mass transfer of SO2 and HCl in acidic flue gas spray drying were established.The influence of the droplet operating parameters on the acid flue gas purification was simulated.The relationship between the droplet displacement in the tower and the inlet flue gas velocity was studied.The influence of atomization humidification and slurry concentration on flue gas purification efficiency was studied experimentally.The experimental results show: Join the humidifying water in spray drying process, the removal efficiency of SO2 and HCl increased, and the removal efficiency of SO2 increased obviously.But the removal efficiency of HCl was not significantly increased.With the increase of the concentration of lime slurry, the removal rate of SO2 and HCl all decreased slightly, and the decrease of the removal rate of SO2 was less than HCl.The simulation results show that: When the inlet smoke velocity is 5 m/s, the displacement range of the droplet is large.With the increase of droplet size, the temperature gradually increased with time.The size of 30 μm, 60 μm and 90 μm droplet reaches stability at 3S, 3S and 4S, respectively.With the increase of particle size, the purification efficiency is increasing.The removal efficiencies of HCl reached equilibrium at 1.5 s, 1.7 s and 2 s, respectively, The removal efficiencies of SO2 reached equilibrium at 2.5 s, 3.5 s and 4 s, respectively.It can be seen that HCl achieves maximum removal efficiency shorter than that of SO2.The removal efficiency of SO2 and HCl increases with the temperature of inlet flue gas increasing.Compared with SO2, the removal rate of HC1 reached stability in the shorter time.
Keywords:Slurry droplets  Acid gas  Purification  Removal efficiency  Spray drying
本文献已被 万方数据 等数据库收录!
点击此处可从《机床与液压》浏览原始摘要信息
点击此处可从《机床与液压》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号