首页 | 本学科首页   官方微博 | 高级检索  
     

炼铁高炉中铜冷却壁焊缝组织的原位金相
引用本文:崔静,瞿体明,曾攀.炼铁高炉中铜冷却壁焊缝组织的原位金相[J].焊接技术,2012,41(7):13-16,78.
作者姓名:崔静  瞿体明  曾攀
作者单位:清华大学机械工程系,北京,100084
摘    要:研究了2种不同高炉铜冷却壁Ⅰ(焊丝为合金),Ⅱ(焊丝为纯铜)管板焊接结构处的原位显微组织.经观察发现,对金相图片进行特殊的原位处理后,可找到焊接熔合线,并由此确定焊缝区、热影响区及母材区铜冷却壁Ⅰ中存在外形显著有别的柱状晶、等轴晶以及相应的过渡晶,其焊缝中存在未熔合、气孔和变向生长柱状晶等焊接缺陷.铜冷却壁Ⅱ晶粒相对均匀,焊缝组织中未发现明显的焊接缺陷.根据研究结果,提出了改进铜冷却壁的焊接工艺.

关 键 词:铜冷却壁  原位金相  显微组织  管板焊接  焊接缺陷

In-situ microstructure analysis for blast furnace copper staves
CUI Jing,QU Ti-ming and ZENG Pan.In-situ microstructure analysis for blast furnace copper staves[J].Welding Technology,2012,41(7):13-16,78.
Authors:CUI Jing  QU Ti-ming and ZENG Pan
Affiliation:(Department of Mechanical Engineering,Tsinghua University,Beijing 100084,China)
Abstract:The in-situ microstructures of weld zone in two kinds of copper staves with different welding procedures was studied.One solder wire was alloy and the other was pure Cu.Observations demonstrated that weld junction was easily to find after in-situ treatment.Copper staveⅠhavestyloid crystals and spherical ones with transitions between them with incomplete fusion,blowhole and deflecting styloid crystals in weld beam.While copper staveⅡconsisted of grains evener and there was no obvious defect in its weld zone.The layer near the surface consists of grains finer and tinier than the close central one.According to the results,some advices for weld procedure improving of copper stave were given in the essay.
Keywords:copper stave  in-situ metallographic phase  microstructure  tube plate welding  weld defect
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号