首页 | 本学科首页   官方微博 | 高级检索  
     

逆变弧焊电源的三相功率因数校正器
引用本文:白志范,孔祥天,杨延军,沈跃.逆变弧焊电源的三相功率因数校正器[J].焊接学报,2007,28(1):61-64.
作者姓名:白志范  孔祥天  杨延军  沈跃
作者单位:吉林大学,材料科学与工程学院,长春,130025
摘    要:对于三相输入的大功率逆变弧焊电源,采用三相升压拓扑进行功率因数校正,以矢量变换的思想研究其调制过程.总体系统的控制采用了双环思想,内环为电流环,用以实现输入电流对电压的相位跟踪,外环为电压环,负责控制输出电压的恒定,并为电流内环提供调制指令,系统采用双环控制,为使系统实现单个开关周期校正控制误差的无差拍控制,整个系统通过TMS320LF2407A DSP芯片控制,采用saber软件进行了仿真辅助分析,给出了电路系统的结构框图和控制方案以及软件流程,实现了电源系统的数字化.试验结果实现了功率因数为1,三相输入电流与输入电压均同相,且为较为标准的正弦波,电流谐波畸变远小于10%的目的,满足了国际上关于谐波限制的标准.

关 键 词:逆变弧焊电源  三相功率因数校正  DSP芯片控制  空间矢量调制
文章编号:0253-360X(2007)01-061-04
收稿时间:2005/12/13 0:00:00
修稿时间:2005-12-13

A PFC stage of three-phase inverter welding power supply
BAI Zhi-fan,KONG Xiang-tian,YANG Yan-jun and SHEN Yue.A PFC stage of three-phase inverter welding power supply[J].Transactions of The China Welding Institution,2007,28(1):61-64.
Authors:BAI Zhi-fan  KONG Xiang-tian  YANG Yan-jun and SHEN Yue
Affiliation:Jilin University, Changchun 130025, China,Jilin University, Changchun 130025, China,Jilin University, Changchun 130025, China and Jilin University, Changchun 130025, China
Abstract:For three phase large welding inverter power supply,three-phase boost topology is introduced as the power factor correction scheme. It's modulation process is analyzed using vector transformation method.We apply two-loop idea in the whole control system.The inner loop is current loop,and it is used to achieve that the input current is in phase with the input voltage using steady-stage deadbeat control to achieve the best dynamic performance.The outer loop is voltage loop,which control the output voltage to be a constant value and offer instruction for the inner current loop.In order to realize the deadbeat-control that can correct the control error in one switch period,TMS320LF2407A DSP is introduced to the control system,and saber software is used for simulation analyses,and the circuit system and software flow chart is put forward.We realize the digitalation of the control system.The experiment result is analyzed.Power factor by experiment is unit.Three phase input current are in phase with input voltage,and they are relative standard sine wave.The total harmonic distortion of the current is less than 10%,and all of this has meet the international harmonic criterrion.
Keywords:inverter welding power supply  three phase power factor correction  digital signal processing  space vector modulation
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《焊接学报》浏览原始摘要信息
点击此处可从《焊接学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏