首页 | 本学科首页   官方微博 | 高级检索  
     

电厂水汽取样管泄漏原因分析
引用本文:王温银,马彦忱,朱敦伦.电厂水汽取样管泄漏原因分析[J].腐蚀科学与防护技术,1999,11(3):185-188.
作者姓名:王温银  马彦忱  朱敦伦
作者单位:1. 中国矿业大学机电工程学院,徐州,221008
2. 徐州商检局,徐州,221000
摘    要:应用金相,SEM、X射线衍射仪和能谱分析技术分析了1Cr18Ni9Ti不锈钢取样管泄漏的原因,结果表明,取样管泄漏是由于取样管运行的工作应力和冷却却的收缩阻力与微量的Cl^-导致的应力腐蚀开裂。

关 键 词:应力腐蚀  拉应力  电厂

LEAKAGE ANALYSIS OF A STEAM SAMPLING TUBE IN A POWER PLANT
WANG Wenyin,MA Yanchen,ZHU Dunlun.LEAKAGE ANALYSIS OF A STEAM SAMPLING TUBE IN A POWER PLANT[J].Corrosion Science and Protection Technology,1999,11(3):185-188.
Authors:WANG Wenyin  MA Yanchen  ZHU Dunlun
Abstract:The leakage of a steam sampling tube made of 1Cr18Ni9Ti stainless steel in a power plant was analyzed using optical microscope,SEM, X\|Ray and chemical analysis. The results showed that the loading stress during service at high temperatures and the axial tensile stress due to the resistence to the contraction of the tube during cooling and trace element of Cl-lead to the SCC of the tube.\=
Keywords:1Cr18Ni9Ti
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《腐蚀科学与防护技术》浏览原始摘要信息
点击此处可从《腐蚀科学与防护技术》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏