Investigation of Plasma Electrolytic Oxidation (PEO) coatings on a Zr-2.5Nb alloy using high temperature/pressure autoclave and tribological tests
Authors:Ying Chen  DO Northwood
Affiliation:
  • Department of Mechanical, Automotive & Materials Engineering, University of Windsor, Windsor, Ontario N9B 3P4, Canada
  • Abstract:A Plasma Electrolytic Oxidation (PEO) process was used to produce thin oxide coatings on a Zr-2.5 wt% Nb alloy. Effects of current density on surface morphologies and wear properties of PEO coatings were investigated and compared to the uncoated substrate and a commercially used black oxide coating. Corrosion properties at ambient and high temperature/pressure conditions were studied using potentiodynamic polarization tests and autoclave tests, respectively. Up to 30-day autoclave experiments were carried out in an aqueous condition of 300 °C and 10 MPa in 0.05 M LiOH solutions. It was found that most of the micro-pores which were produced during the PEO treatment were closed after the autoclave experiments. PEO coatings had larger weight gains in the first 10 exposure days than the black oxide coating. However, after 10 days, the corrosion rate of black oxide coating accelerated and exhibited a similar weight gain to PEO coatings after 30 days. PEO coatings prepared at low current densities had lower weight gains. Although the black oxide coating exhibited a good corrosion resistance, it had a much lower wear resistance than the PEO coatings. Compared with the uncoated substrate, all PEO coatings had a higher corrosion resistance, lower weight gain during autoclave tests and better wear resistance.
    Keywords:PEO  Zr-2  5Nb  Potentiodynamic polarization test  Pin-on-disc test  Autoclave test  Corrosion and wear resistance
    本文献已被 ScienceDirect 等数据库收录!
    设为首页 | 免责声明 | 关于勤云 | 加入收藏

    Copyright©北京勤云科技发展有限公司  京ICP备09084417号