首页 | 本学科首页   官方微博 | 高级检索  
     

大柳塔热电厂高压加热器的运行经济性分析
引用本文:陈秀萍,贺军全,张金良,乔正瑜.大柳塔热电厂高压加热器的运行经济性分析[J].汽轮机技术,2003,45(6):387-389.
作者姓名:陈秀萍  贺军全  张金良  乔正瑜
作者单位:神华集团神东公司大柳塔热电厂,陕西,神木,719315
摘    要:高压加热器由于泄漏不能正常投运,对机组的安全经济运行带来严重影响,通过定量分析、对高压加热器进行改造,提高了高压加热器的投入率,为机组的安全运行提供了保障,降低了发电成本,提高了全厂的热经济效率。

关 键 词:高压加热器  定量分析  结构改造
文章编号:1001-5884(2003)06-0387-03
修稿时间:2003年9月5日

Analysis on the Thermo-economics of High Pressure Heater for the 12MW Power Unit
CHEN Xiu-ping,HE Jun-quan,ZHANG Jin-liang,QIAO Zheng-yu.Analysis on the Thermo-economics of High Pressure Heater for the 12MW Power Unit[J].Turbine Technology,2003,45(6):387-389.
Authors:CHEN Xiu-ping  HE Jun-quan  ZHANG Jin-liang  QIAO Zheng-yu
Abstract:The high-pressure heater couldn't be put into use because of leakage. It has severely impacted the safe operating of the electricity generator. Based on the quantitative analysis, the high-pressure heater was rebuilt, so the input-rate of the heater has been improved, the operation safety of power unit guarantees, the electricity generating cost reduces, and the plant thermo-economics increases.
Keywords:high pressure heater  quantitative analysis  thermo-economics