首页 | 本学科首页   官方微博 | 高级检索  
     


Effects of evaporative inlet and aftercooling on the recuperated gas turbine cycle
Authors:Ashraf M Bassily
Affiliation:

1 Nuclear Engineering Laboratory, Iowa State University, Ames, IA 50011, USA

Abstract:Inlet air cooling and cooling of the compressor discharge using water injection boost both efficiency and power of gas turbine cycles. Four different layouts of the recuperated gas turbine cycle are presented. Those layouts include the effect of evaporative inlet and aftercooling (evaporative cooling of the compressor discharge). A parametric study of the effect of turbine inlet temperature (TIT), ambient temperature, and relative humidity on the performance of all four layouts is investigated. The results indicate that as TIT increases the optimum pressure ratio increases by 0.45 per 100 K for the regular recuperated cycle and by 1.4 per 100 K for the recuperated cycle with evaporative aftercooling. The cycles with evaporative aftercooling have distinctive pattern of performance curves and higher values of optimum pressure ratios. The results also showed that evaporative cooling of the inlet air could boost the efficiency by up to 3.2% and that evaporative aftercooling could increase the power by up to about 110% and cycle efficiency by up to 16%.
Keywords:Evaporative  Inlet cooling  Aftercooling  Injected water  Gas turbine  Pressure ratio
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏