首页 | 本学科首页   官方微博 | 高级检索  
     


Design and partial load exergy analysis of hybrid SOFC–GT power plant
Affiliation:1. DETEC, Università degli Studi di Napoli Federico II, P.le Tecchio80, 80125 Naples, Italy;2. Dipartimento di Scienza degli Alimenti, Università degli Studi di Napoli Federico II, Via Università 100, Portici, NA 80055, Italy;1. Department of Chemical Engineering, Faculty of Engineering, Burapha University, Chonburi 20131, Thailand;2. Department of Chemical Engineering, Faculty of Engineering, Srinakharinwirot University, Nakorn Nayok 26120, Thailand;3. School of Chemical Engineering, Faculty of Engineering, King Mongkut''s Institute of Technology Ladkrabang, Bangkok 10520, Thailand;4. Computational Process Engineering Research Unit, Department of Chemical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok 10330, Thailand;1. Faculty of Engineering, Urmia University, Urmia, Iran;2. Faculty of Mechanical Engineering, University of Tabriz, Tabriz, Iran;3. Center for Sustainable Energy Solutions (CENSE), University of Stavanger, N-4036 Stavanger, Norway;1. McMaster University, Department of Chemical Engineering, Hamilton, ON, Canada;2. Leidos Research Support Team, Leidos, Morgantown, WV, USA;3. US Department of Energy, National Energy Technology Laboratory, Morgantown, WV, USA
Abstract:This paper presents a full and partial load exergy analysis of a hybrid SOFC–GT power plant. The plant basically consists of: an air compressor, a fuel compressor, several heat exchangers, a radial gas turbine, mixers, a catalytic burner, an internal reforming tubular solid oxide fuel cell stack, bypass valves, an electrical generator and an inverter. The model is accurately described. Special attention is paid at the calculation of SOFC overpotentials. Maps are introduced, and properly scaled, in order to evaluate the partial load performance of turbomachineries. The plant is simulated at full-load and part-load operation, showing energy and exergy flows trough all its components and thermodynamic properties at each key-point. At full-load operation a maximum value of 65.4% of electrical efficiency is achieved. Three different part-load strategies are introduced. The off-design operation is achieved handling the following parameters: air mass flow rate, fuel mass flow rate, combustor bypass, gas turbine bypass, avoiding the use of a variable speed control system. Results showed that the most efficient part-load strategy corresponded to a constant value of the fuel to air ratio. On the other hand, a lower value of net electrical power (34% of nominal load) could be achieved reducing fuel flow rate, at constant air flow rate. This strategy produces an electrical efficiency drop that becomes 45%.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号