1000MW火电机组给水泵组配置对机组运行的影响 |
| |
引用本文: | 沈坚,黄兆华,陈昕,王建梅,张春琳,冯俊涛.1000MW火电机组给水泵组配置对机组运行的影响[J].节能,2013,32(1):39-42,2. |
| |
作者姓名: | 沈坚 黄兆华 陈昕 王建梅 张春琳 冯俊涛 |
| |
作者单位: | 1. 中南电力设计院,湖北武汉,430071 2. 武汉大学动力与机械学院动力系,湖北武汉,430072 |
| |
摘 要: | 结合国电汉川电厂1000MW机组的给水泵配置情况,分析比较多种给水泵配置方案的差异。在此基础上,针对无电动给水泵配置的情况,分析其设备运行的安全性和经济性,以及该配置方案对机组运行的影响。
|
关 键 词: | 汽动给水泵组 电动给水泵组 最优配置 机组运行 |
Influence of boiler feed pump configuration on the 1000MW power plant unit operation |
| |
Affiliation: | SHEN Jian,HUANG Zhao-hua,CHEN Xin,et al(Central Southern China Electric Power Design Institute,Wuhan 430071,China) |
| |
Abstract: | Differences among a variety of feed-water pump configuration are anglysed and compared based on the 1000MW units of Hanchuan power plant feed-water pump configuration.The safety and economy of equipment operation for non-motor-driven feed-water pump configuration and the effect of boiler feed pump configuration on the unit operation are analysed. |
| |
Keywords: | turbine-driven feed-water pump motor-driven feed-water pump optimal configuration unit operation |
本文献已被 CNKI 万方数据 等数据库收录! |
|