首页 | 本学科首页   官方微博 | 高级检索  
     


Fin-tube junction effects on flow and heat transfer in flat tube multilouvered heat exchangers
Authors:DK Tafti  J Cui
Affiliation:a Mechanical Engineering Department, Virginia Tech, 105 Randolph Hall, Blacksburg, VA 24061, USA
b Mechanical Engineering Department, Center for Electric Power, Tennessee Technological University, Cookeville, TN 38505, USA
Abstract:Three-dimensional simulations of four louver-tube junction geometries are performed to investigate the effect on louver and tube friction and heat transfer characteristics. Three Reynolds numbers, 300, 600 and 1100, based on bulk velocity and louver pitch are calculated. Strong three-dimensionality exists in the flow structure in the region where the angled louver transitions to a flat landing adjoining the tube surface, whereas the flow on the angled louver far from the tube surface is nominally two-dimensional. Due to the small spatial extent of the transition region, its overall impact on louver heat transfer is limited, but the strong unsteady flow acceleration on the top louver surface augments the heat transfer coefficient on the tube surface by over 100%. In spite of the augmentation, the presence of the tube lowers the overall Nusselt number of the heat exchanger between 25% and 30%. Comparisons with correlations derived from experiments on full heat exchanger cores show that computational modeling of a small subsystem can be used reliably to extract performance data for the full heat exchanger.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏