首页 | 本学科首页   官方微博 | 高级检索  
     


Use of oscillating heat pipe technique as extended surface in wire-on-tube heat exchanger for heat transfer enhancement
Authors:Atipoang Nuntaphan  Sanparwat Vithayasai  Nat Vorayos  Nattanee Vorayos  Tanongkiat Kiatsiriroat
Affiliation:1. Thermal Technology Research Laboratory, Mae Moh Training Center, Electricity Generating Authority of Thailand, Mae Moh, Lampang 52220, Thailand;2. Technology Licensing Office, Chiang Mai University, Chiang Mai 50200, Thailand;3. Department of Mechanical Engineering, Chiang Mai University, Chiang Mai 50200, Thailand
Abstract:This paper presents the performance of a wire-on-tube heat exchanger of which the wire is an oscillating heat pipe. The experiments for this heat exchanger were performed in a wind tunnel by exchanging heat between hot water flowing inside the heat exchanger tubes and air stream flowing across the external surface. R123, methanol and acetone were selected as working fluids of the oscillating heat pipe. The inlet water temperature was varied from 45 to 85 °C while the inlet air temperature was kept constant at 25 °C.
Keywords:Heat transfer enhancement  Performance testing  Wire-on-tube  Oscillating heat pipe  Heat exchanger
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号