首页 | 本学科首页   官方微博 | 高级检索  
     

新型失压计录监测器的应用
引用本文:万 彦,陈劲游.新型失压计录监测器的应用[J].电网与水力发电进展,2009,25(12):54-56.
作者姓名:万 彦  陈劲游
作者单位:河南信阳供电公司市场营销部,河南 信阳 464000;中山市通易达电子有限公司,广东 中山 528403
摘    要:鉴于失压断流计时仪在电能计量装置发生故障时计算故障期间电能表漏计电量的(只知道断流失压时间,然后由失压时间计算出嘴部电量),提出新型失压检测器。该监测器不需要假定三相电流平衡,也无需知道计量二次回路接线阻抗就能准确计算出失压时漏计的电量。

关 键 词:失压计录监测器  电能计量  追补电量

Application of A New No-Voltage Monitor
Authors:WAN Yan and CHEN Jin-you
Affiliation:WAN Yan, CHEN Jin-you ( 1.Henan Xinyang Power Supply Company ; Xinyang 464000, Henan Province, China; 2.Zhongshan Tongyida Electronics Co., Ltd, Zhongshan 528403, Guangdong Province, China)
Abstract:With reference to the inconveniences of the no-voltage time recording device in calculating the missing electricity not measured during the period when the energy meter fails, this paper presents a new no-voltage monitor. The monitor is able to work out precisely the missing electricity not measured at no-voltage without assuming the three-phase current is in balance, and without knowing the second-loop connection impedance.
Keywords:loss-voltage  energy measurement  power-value  make-up electricity
本文献已被 维普 万方数据 等数据库收录!
点击此处可从《电网与水力发电进展》浏览原始摘要信息
点击此处可从《电网与水力发电进展》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号