首页 | 本学科首页   官方微博 | 高级检索  
     


Cyclophosphamide removal from water by nanofiltration and reverse osmosis membrane
Authors:L Wang  A Pfohl-Leszkowicz  B Marion
Affiliation:a Laboratoire de Génie Chimique (UMR 5503), 5 rue Paulin Talabot, 31106 Toulouse, France
b Laboratoire de Génie Chimique (UMR 5503), Université de Toulouse, Université Paul Sabatier, 31062 Toulouse Cedex 09, France
c Laboratoire de biophysique et bio-analyse, faculté de pharmacie, Université de Montpellier, BP 14491, 15 avenue Charles-Flahault, 34093 Montpellier, France
Abstract:The rejection of cyclophosphamide (CP) by nanofiltration (NF) and reverse osmosis (RO) membranes from ultrapure (Milli-Q) water and membrane bioreactor (MBR) effluent was investigated. Lyophilization-extraction and detection methods were first developed for CP analysis in different water matrices. Experimental results showed that the RO membrane provided excellent rejection (>90%) under all operating conditions. Conversely, efficiency of CP rejection by NF membrane was poor: in the range of 20-40% from Milli-Q water and around 60% from MBR effluent. Trans-membrane pressure, initial CP concentration and ionic strength of the feed solution had almost no effect on CP retention by NF. On the other hand, the water matrix proved to have a great influence: CP rejection rate by NF was clearly enhanced when MBR effluent was used as the background solution. Membrane fouling and interactions between the CP and water matrix appeared to contribute to the higher rejection of CP.
Keywords:Cyclophosphamide  Nanofiltration  Reverse osmosis  MBR effluent  Removal
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号