首页 | 本学科首页   官方微博 | 高级检索  
     

大型火电厂钢结构主厂房框排架结构拟静力试验研究
引用本文:薛建阳,梁炯丰,彭修宁,刘祖强,茅荣华.大型火电厂钢结构主厂房框排架结构拟静力试验研究[J].建筑结构学报,2012,33(8):11-15.
作者姓名:薛建阳  梁炯丰  彭修宁  刘祖强  茅荣华
作者单位:1.西安建筑科技大学 土木工程学院, 陕西西安 710055; 2.东华理工大学 建筑工程学院, 江西南昌 330013;3.广西大学 土木建筑工程学院, 广西南宁 530004
基金项目:国家自然科学基金项目,中国博士后科学基金项目,长江学者和创新团队发展计划资助项目
摘    要:对1榀3跨5层的钢框排架主体结构进行了低周反复加载试验,观测了框排架的破坏形态,得到了试件的荷载-位移滞回曲线、骨架曲线,分析了钢框排架的破坏机制、滞回性能、延性、耗能能力、刚度退化等力学性能。结果表明:钢框排架结构的破坏机制为先梁端后柱端出现塑性铰的混合破坏机制,滞回曲线较饱满,整体位移延性系数大于4.0,等效黏滞阻尼系数达到0.189。钢框排架结构体系总体上表现出良好的抗震能力,适合高烈度抗震设防区采用。模型结构的层间位移角在底层和第二层较大,为薄弱层;煤斗梁地震反应较强,设计时要特别注意。

关 键 词:火电厂  抗震性能  框排架  拟静力试验  

Quasi-static test of steel frame-bent structures of large thermal power plant main buildings
XUE Jianyang,LIANG Jiongfeng,PENG Xiuning,LIU Zuqiang,MAO Ronghua.Quasi-static test of steel frame-bent structures of large thermal power plant main buildings[J].Journal of Building Structures,2012,33(8):11-15.
Authors:XUE Jianyang  LIANG Jiongfeng  PENG Xiuning  LIU Zuqiang  MAO Ronghua
Affiliation:1.College of Civil Engineering, Xi’an University of Architecture & Technology, Xi’an 710055, China;2.College of Architecture Engineering, East China Institute of Technology, Nanchang 330013, China;3.College of Civil Engineering and Architecture, Guangxi University, Nanning 530004, China
Abstract:Through the experimental study on the model of a three-bay and five-story steel frame-bent structures under low cycle reversed loading,the failure condition of frame-bent structures was observed.The load-displacement,hysteretic loops and skeleton curve of tested model were obtained.The failure mechanism,hysteretic behavior,ductility,energy dissipation capacity and stiffness degradation were investigated.The results show that the failure mechanism of steel frame-bent structures is the first occurrence of beam-hinge and then column-hinge mechanism.The hysteretic loops are plump.The average of the overall ductility factors is greater than 4.The equivalent viscous damping coefficient is 0.189.The steel frame-bent structure exhibits excellent seismic behavior,and can be adopted in high seismic fortification zones.The inter-story drift is relatively large on the bottom story and the second story,namely the weak stories.And there are large seismic forces at the coal hopper beams,which must be paid attention in design.
Keywords:thermal power plant  frame-bent structure  quasi-static test  seismic behavior
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《建筑结构学报》浏览原始摘要信息
点击此处可从《建筑结构学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号