首页 | 本学科首页   官方微博 | 高级检索  
     

刻楞式胶合木别墅外墙保温性能测试分析
引用本文:轩浩,胡志伟,杨勇.刻楞式胶合木别墅外墙保温性能测试分析[J].低温建筑技术,2017,39(10):136-140.
作者姓名:轩浩  胡志伟  杨勇
作者单位:1. 黑龙江省建筑设计研究院,哈尔滨,150008;2. 黑龙江科技大学,哈尔滨,150022
摘    要:采用热流计法对牡丹江某刻楞式胶合木别墅外墙的保温性能进行检测。通过对室内外温度、墙体热流检测数据的测试,计算得出实测传热系数。将实测传热系数与PKPM软件计算值进行对比,发现实测传热系数比软件计算值高3.3%。进行墙体热成像分析后,找出数据差异原因,并提出改进措施。

关 键 词:木刻楞  胶合木  别墅  外墙保温性能

RESEARCH ON EXTERNAL THERMAL INSULATION PERFORMANCE TEST OF MUKEDEN VILLA
XUAN Hao,HU Zhiwei,YANG Yong.RESEARCH ON EXTERNAL THERMAL INSULATION PERFORMANCE TEST OF MUKEDEN VILLA[J].Low Temperature Architecture Technology,2017,39(10):136-140.
Authors:XUAN Hao  HU Zhiwei  YANG Yong
Abstract:The heat preservation performance of Mudanjiang carved wooden villa exterior wall was tested by heat flow meter.Through the indoor and outdoor temperature,wall heat flow test data calculation,obtain the measured heat transfer coefficient.The measured heat transfer coefficient is compared with the calculated value of PKPM software.It is found that the measured heat transfer coefficient is 33.3% higher than the calculated value of software.Mter the thermal imaging analysis of the wall,the reasons for data differences were found out and the improvement measures were put forward.
Keywords:wood carved leng  glued wood  villa  external wall insulation performance
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号