首页 | 本学科首页   官方微博 | 高级检索  
     

金属复合屋面板用硬质聚氨酯泡沫的力学性能
引用本文:黄莉,邓华,王宸.金属复合屋面板用硬质聚氨酯泡沫的力学性能[J].建筑材料学报,2014,17(2):320-326.
作者姓名:黄莉  邓华  王宸
作者单位:浙江大学空间结构研究中心,浙江杭州310058;浙江大学空间结构研究中心,浙江杭州310058;浙江大学空间结构研究中心,浙江杭州310058
摘    要:针对金属复合屋面板用硬质聚氨酯泡沫材料分别进行了发泡方向和涂层方向的拉伸、压缩力学性能试验,对各向基本力学参数进行了测定.结果表明:硬质聚氨酯泡沫材料在发泡方向和涂层方向的拉伸和压缩力学性能不相同,不能简单看作为各向同性材料.在拉伸情况下,硬质聚氨酯泡沫材料呈脆性破坏,但压缩时存在明显屈服平台且无明显破坏特征.硬质聚氨酯泡沫材料发泡方向与涂层方向的力学参数差异明显,其发泡方向的拉、压弹性模量仅约为涂层方向的1/2,拉伸极限强度及压缩屈服强度也都明显低于涂层方向.根据试验数据,建议了适用于硬质聚氨酯泡沫的横观各向同性本构模型并对主要参数进行了拟合.

关 键 词:硬质聚氨酯泡沫    金属复合屋面板    力学性能    本构模型    横观各向同性模型
收稿时间:2012/10/30 0:00:00
修稿时间:2012/12/13 0:00:00

Mechanical Properties of Rigid Polyurethane FoamUsed in Metal Composite Roof Panels
HUANG Li,DENG Hua and WANG Chen.Mechanical Properties of Rigid Polyurethane FoamUsed in Metal Composite Roof Panels[J].Journal of Building Materials,2014,17(2):320-326.
Authors:HUANG Li  DENG Hua and WANG Chen
Affiliation:Space Structures Research Center, Zhejiang University, Hangzhou 310058, China;Space Structures Research Center, Zhejiang University, Hangzhou 310058, China;Space Structures Research Center, Zhejiang University, Hangzhou 310058, China
Abstract:For the rigid polyurethane foam used in metal composite roof panels, tensile and compression tests were carried out in its foaming and coating directions respectively, and basic mechanical parameters in those characteristic directions were obtained. The results reveal that the rigid polyurethane foam cannot be regarded as isotropic material due to the differences of the tensile and compressive behaviors between the foaming direction and the coating direction. Brittle fracture occurs in the tensile testing. However, there are yield platform and lack of damage in the compressive case. The mechanical parameters of the rigid polyurethane foam in the foaming direction and the coating direction are also different. The tensile and compressive elastic moduli in the foaming direction are only half of those in the coating direction, while the tensile ultimate strength and compression yield strength in the foaming direction are also less than that in the coating direction. Based on the data in test, a transversely isotropic constitutive model suitable for the rigid polyurethane foam is suggested and main parameters of the model are fitted in the end.
Keywords:rigid polyurethane foam  metal composite roof panel  mechanical property  constitutive model  transversely isotropic model
点击此处可从《建筑材料学报》浏览原始摘要信息
点击此处可从《建筑材料学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号