摘    要:基于两榀大尺度后张有粘结预应力全型钢混凝土框架的静力试验,对预应力型钢混凝土框架梁的抗裂度进行了测试和理论研究。应用混凝土基本原理、GB 50010—2002《混凝土结构设计规范》和ACI318—05规范中抗裂度公式推导了考虑次轴力的预应力型钢混凝土框架的抗裂度计算公式,用试验值进行验证。结果表明:按照混凝土基本原理推...

关 键 词:预应力型钢混凝土框架  静力试验  抗裂度  次轴力

EXPERIMENTAL INVESTIGATION AND CRACK RESISTANCE ANALYSIS ON LARGE SCALE PRESTRESSED STEEL REINFORCED CONCRETE FRAME
Xiong Xueyu,Gao Feng,Li Yaming.EXPERIMENTAL INVESTIGATION AND CRACK RESISTANCE ANALYSIS ON LARGE SCALE PRESTRESSED STEEL REINFORCED CONCRETE FRAME[J].Industrial Construction,2011,41(12):16-19.
Authors:Xiong Xueyu  Gao Feng  Li Yaming
Affiliation:1.Department of Building Engineering,Tongji University,Shanghai 200092,China;2.Key Laboratory of Advanced Civil Engineering Materials(Tongji University),Ministry of Education,Shanghai 200092,China; 3.Shanghai Institute of Architectural Design & Research Co.Ltd,Shanghai 200041,China)
Abstract:Based on the static test of large-scaled prestressed steel concrete frames,the crack resistance of such frame beams was tested and investigated.In this paper,according to theory of reinforced concrete members and the formulas of crack resistance in Code for Design of Concrete Structures(GB 50010—2002)and code ACI 318—05,the formulas of cracking moment considering secondary axial forces were deduced and verified by test results.Conclusion can be drawn as follows: the calculation error of formulas derived from theory of reinforced concrete members is small,generally less than 6%;the error of formulas derived from GB 50010—2002 is about 10%,which can meet the needs of engineering and simply to be calculated;cracking moment calculated by formulas derived from code ACI 318—05 is less than test result,it is unsafe for engineering application.
Keywords:prestressed steel reinforced concrete frames  static test  crack resistance  secondary axial force