首页 | 本学科首页   官方微博 | 高级检索  
     

AP1000冷凝水回流相关设计优化简介
引用本文:马柏松,庄亚平,郄卫青.AP1000冷凝水回流相关设计优化简介[J].核动力工程,2021,41(5):79-83.
作者姓名:马柏松  庄亚平  郄卫青
摘    要:

关 键 词:非能动堆芯冷却系统(PXS)  冷凝水回流  安全停堆  

A Brief Introduction of Design Optimization for AP1000 Condensation Return
Ma Baisong,Zhuang Yaping,Qie Weiqing.A Brief Introduction of Design Optimization for AP1000 Condensation Return[J].Nuclear Power Engineering,2021,41(5):79-83.
Authors:Ma Baisong  Zhuang Yaping  Qie Weiqing
Abstract:During any non-LOCA event, the average temperature of the reactor cooling system (RCS) should be decreased to 215.6℃within 36 hours in AP1000 nuclear power plant. However, this goal cannot be achieved because the rate of condensate return was far lower than that expected. Through the analysis and verification of the dome condensation drop test, the path of condensation loss was determined. Therefore, a series of the design modifications to the polar crane girder, the internal stiffener and the condensation return gutter were carried out. Lastly, the safety shutdown temperature evaluation showed that the AP1000 plant could reduce the RCS average temperature to 215.6℃ within 34.6 hours after the loss of normal feedwater and the loss of off-site power concurrently.
Keywords:
点击此处可从《核动力工程》浏览原始摘要信息
点击此处可从《核动力工程》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号