作者单位:Takasaki Radiation Chemistry Research Establishment,Japan Atomic Energy Research Institute(JAERI),1233 Watanuki,Takasaki,Gumma 370-1292,Japan,Laboratory for Measurements of Technological Doses(LMTD),Institute of Nuclear Chemistry and Technology(INCT),ul.Dorodna16,03-195Warszawa,Poland,Laboratory for Measurements of Technological Doses(LMTD),Institute of Nuclear Chemistry and Technology(INCT),ul.Dorodna16,03-195Warszawa,Poland
摘    要:1 Introduction With the rapid development of radiation process- ing by electron beam irradiation in China, it is more Ever since 1962, alanine/EPR dosimetry system and more needed to establish a transfer dosimetryhas been used to measure the absorbed dose.1] Its ad- system with high accuracy to assure the quality of thevantages over othe…

关 键 词:钴γ射线照射  不确定性  电子束照射  丙氨酸薄膜放射性剂量计

Dose intercomparison studies for 60Co gamma-ray and electron beam irradiation in the year 2002
Takuji KOJIMA,Zofia PEIMEL-STUGLIK,Slawomir FABISIAK.Dose inter-comparison studies for ^60Co gamma-ray and electron beam irradiation in the year 2002[J].Nuclear Science and Techniques,2004,15(3):166-173.
Authors:LIN Min  Takuji KOJIMA  Zofia PEIMEL-STUGLIK  CHEN Yun-Dong  CUI Ying  CHEN Ke-Sheng  LI Hua-Zhi  XIAO Zhen-hong  Slawomir FABISIAK
Affiliation:1. Radiometrology Center, China Institute of Atomic Energy ( CIAE), Beijing 102413, China
2. Takasaki Radiation Chemistry Research Establishment, Japan Atomic Energy Research Institute(JAERI), 1233 Watanuki, Takasaki, Gumma 370-1292, Japan
3. Laboratory for Measurements of Technological Doses (LMTD), Institute of Nuclear Chemistry and Technology (INCT), ul. Dorodna 16, 03-195 Warszawa, Poland
Abstract:Dose inter-comparison studies for 60Co γ-ray and 10MeV electron beam irradiation were carried out from July to October in 2002. The purpose of the studies was to check the reliability of the alanine-PE film dosimeters made by CIAE, which will be used as transfer standard dosimetry system mainly for electron beam irradiation.The expanded uncertainty of CIAE alanine/EPR dosimetry system was 4.1% for doses not higher than 10 kGy and 5.4% for those above 10 kGy (k=2). CIAE alanine-PE film dosimeters were sent to JAERI, RISO (National Laboratory in Denmark) and INCT respectively, which were irradiated by 60Co gamma-rays or electron beams in each laboratory. The irradiated dosimeters were then sent back to CIAE for electron paramagnetic resonance (EPR) analysis.The agreements were obtained to be ±1.9% for gamma-ray dose measurement and ±4.3% for electron beam dose measurement, which were all within the combined uncertainty of the reference and CIAE alanine/EPR dosimetry system. Furthermore, the overall mean ratio was found to be 0.995 with 1.8% in the coefficient of variation (CV). The preliminary inter-comparison studies indicated that CIAE film alanine/EPR dosimetry system had the potential to be used as a transfer dosimetry system for high dose measurement.
Keywords:Alanine film dosimeter  Dose inter-comparison  Uncertainty    60Co gamma-ray irradiation  Electron        beam irradiation