Obtaining low energy γ dose with CMOS sensors |
| |
引用本文: | 王芳,王明远,刘玉芳,马春旺,常乐.Obtaining low energy γ dose with CMOS sensors[J].核技术(英文版),2014(6). |
| |
作者姓名: | 王芳 王明远 刘玉芳 马春旺 常乐 |
| |
基金项目: | Supported by National Natural Science Foundation of China(No.10905017);the Science and Technology Innovation Team Support Plan in Henan Province(No.13IRTSTHN016) |
| |
摘 要: | A method is established for measuring low energy γ-rays dose by using CMOS sensors without any X-/γ-ray converters. Gamma-ray source of241 Am and152Eu are used to test the system. Based on gray value, an analysis method is proposed to obtain the γ-ray dose. Cumulative dose is determined by correlating the gray value to the dose readings of standard dosimeters. The relationship between gray value and the cumulative dose of γ-rays are trained by using back propagation neural network with BFGS algorithm. After comparison, it shows that BFGS algorithm trainings are suitable for different γ-ray sources under higher error condition. These indicate the feasibility of measuring low energy γ-ray dose by using common CMOS image sensors.
|
关 键 词: | CMOS image sensor Low energy γ-ray detection Image processing BP neural network BFGS algorithm |
本文献已被 CNKI 等数据库收录! |
|