摘    要:选取3种市售β-兴奋剂化学发光酶免疫分析检测试剂盒,从线性关系、灵敏度、选择性、检出限、准确度、重复性及变异性等方面进行实验,并经农业部1025号公告—18—2008中高效液相色谱—串联质谱法验证比较,初步建立了一套化学发光酶免疫分析检测试剂盒质量评价方法。结果表明:沙丁胺醇、盐酸克伦特罗、莱克多巴胺3种试剂盒在测定范围内线性关系良好,灵敏度分别为0.7、1.8、1.0 ng/mL,检出限分别为0.2、0.1、0.2 ng/mL,猪肝、猪肉和牛肉的回收率在81.9%~115.2%之间,重复性变异系数为3.3%~9.7%,批间变异系数为9.9%~16.5%,交叉反应率均符合产品说明书要求,可以用于猪肝、猪肉、牛肉样品中沙丁胺醇、盐酸克伦特罗、莱克多巴胺的残留检测。

关 键 词:沙丁胺醇  盐酸克伦特罗  莱克多巴胺  化学发光酶免疫分析  试剂盒  评价方法  

Evaluation of Three β-Adrenergic Agonist Chemiluminescence Enzyme Immunoassay Detection Kits
NING Xiao,ZHANG Weiqing,LIANG Ruiqiang,CAO Jin,ZHANG Qingsheng.Evaluation of Three β-Adrenergic Agonist Chemiluminescence Enzyme Immunoassay Detection Kits[J].Food Science,2016,37(12):238-242.
Authors:NING Xiao  ZHANG Weiqing  LIANG Ruiqiang  CAO Jin  ZHANG Qingsheng
Affiliation:National Institutes for Food and Drug Control, Beijing 100050, China
Abstract:In this study, three commercially available β-adrenergic agonist chemiluminescence enzyme immunoassay(CLEIA) detection kits were evaluated in term of regression curve, sensitivity, specificity, detection limit, accuracy,reproducibility and inter-assay coefficients of variation. The validated test between CLEIA and high performance liquidchromatography-tandem mass spectrometry (HPLC-MS/MS) was done. This work established a methodology for thequality evaluation of CLEIA test kits. The results showed that three detection kits all had good linearity. Their sensitivitiesfor three β-adrenergic agonists, salbutamol, clenbuterol hydrochloride and ractompaine, were 0.7, 1.8, and 1.0 ng/mL, andthe corresponding limits of detection (LODs) were 0.2, 0.1, and 0.2 ng/mL, respectively. The recovery rates from spikedpork liver, pork and beef were between 81.9% and 115.2%. The reproducibility and inter-assay coefficients of variationwere 3.3%–9.7% and 9.9%–16.5%, respectively. Cross-reactivity rate was in compliance with the product specificationrequirements. The three kits can be used in detection of salbutamol, clenbuterol hydrochloride and ractompaine residues inpork liver, pork and beef.
Keywords:salbutamol  clenbuterol hydrochloride  ractompaine  chemiluminescence enzyme immunoassay (CLEIA)  kit  evaluation method  
本文献已被 CNKI 等数据库收录!
点击此处可从《食品科学》浏览原始摘要信息
点击此处可从《食品科学》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号