首页 | 本学科首页   官方微博 | 高级检索  
     

食品接触硅橡胶中十二甲基环六硅氧烷的检测及不确定度分析
引用本文:高建国,贺炳慧,张辉珍,田 敏,宋晓云,于洪观.食品接触硅橡胶中十二甲基环六硅氧烷的检测及不确定度分析[J].食品科学,2017,38(4):265-269.
作者姓名:高建国  贺炳慧  张辉珍  田 敏  宋晓云  于洪观
作者单位:1.青岛出入境检验检疫局,山东 青岛 266001;2.山东科技大学化学与环境工程学院,山东 青岛 266590; 3.青岛市食品药品检验研究院,山东 青岛 266071;4.青岛科标检测研究院有限公司,山东 青岛 266042
基金项目:科技部质检行业公益项目(201410083)
摘    要:采用气相色谱质谱联用仪对其迁移到食品模拟液中的十二甲基环六硅氧烷(dodecamethylcyclohexasiloxane,D6)进行定性定量分析,并对实验过程中可能产生的不确定度进行总结分析。结果发现,利用气相色谱-质谱联用仪检测食品接触硅橡胶烤盘垫迁移出的D6含量为125.6 mg/kg,由D6标准品曲线拟合产生的相对标准不确定度较高,可达到0.028 5。整个实验的合成不确定度为0.046 5,相对扩展不确定度为0.093,而由不确定度引起的D6含量变化为±11.68 mg/kg。

关 键 词:硅橡胶  安全性  气相色谱-质谱法  不确定度  

Determination and Uncertainty Analysis of Dodecamethylcyclohexasiloxane in Food Contact Silicone Rubber
GAO Jianguo,HE Binghui,ZHANG Huizhen,TIAN Min,SONG Xiaoyun,YU Hongguan.Determination and Uncertainty Analysis of Dodecamethylcyclohexasiloxane in Food Contact Silicone Rubber[J].Food Science,2017,38(4):265-269.
Authors:GAO Jianguo  HE Binghui  ZHANG Huizhen  TIAN Min  SONG Xiaoyun  YU Hongguan
Affiliation:1. Qingdao Entry-Exit Inspection and Quarantine Bureau, Qingdao 266001, China; 2. College of Chemical and Environmental Engineering, Shandong University of Science and Technology, Qingdao 266590, China; 3. Qingdao Institute for Food and Drug Control, Qingdao 266071, China; 4. Qingdao Science Standard Testing Research Institute Co. Ltd., Qingdao 266042, China
Abstract:In this paper, a gas chromatograph-mass spectrometry (GC-MS) was used to qualitatively and quantitatively analyze the migration of dodecamethylcyclohexasiloxane (D6) from food contact silicone rubber into a liquid food stimulant. Meanwhile, the uncertainty of each variable was also analyzed. The most important factors that affect the results of the experiment were identified. GC-MS analysis indicated that the migration level of D6 was about 125.6 mg/kg from a baking mat made from food contact silicone rubber . We summed up five kinds of uncertainties throughout the experimental process. The highest uncertainty was resulted from the standard curve fitting of D6, which was up to 0.028 5. The combined standard uncertainty was 0.046 5 and the relative expanded uncertainty was 0.093. The amount of D6 analyzed by GC-MS varied in the range of ± 11.68 mg/kg taking the experimental uncertainties into consideration.
Keywords:silicone rubber  safety  gas chromatograph-mass spectrometry (GC-MS)  uncertainty  
本文献已被 CNKI 等数据库收录!
点击此处可从《食品科学》浏览原始摘要信息
点击此处可从《食品科学》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号