首页 | 本学科首页   官方微博 | 高级检索  
     

高效液相色谱—二极管阵列检测法测定原料乳中的舒巴坦
引用本文:刘珊珊,单艺,满朝新,谢鲲昊,卢雁,胡惠秩,阎天文,姜毓君.高效液相色谱—二极管阵列检测法测定原料乳中的舒巴坦[J].食品工业科技,2012,33(16):64-66.
作者姓名:刘珊珊  单艺  满朝新  谢鲲昊  卢雁  胡惠秩  阎天文  姜毓君
作者单位:1. 东北农业大学食品学院,乳品科学教育部重点实验室,黑龙江哈尔滨150030
2. 国家乳业工程技术研究中心,黑龙江哈尔滨,150086
3. 东北农业大学食品学院,乳品科学教育部重点实验室,黑龙江哈尔滨150030 国家乳业工程技术研究中心,黑龙江哈尔滨150086
基金项目:国家科技支撑计划课题(2012BAK17B04);国家科技支撑计划课题(2009BADB9B06)
摘    要:建立了利用高效液相色谱-二极管阵列法(high-performance liquid chromatography-photodiode array,HPLC-PDA)测定原料乳中舒巴坦含量的方法。采用C18色谱柱,以5.44g/L磷酸二氢钾溶液(pH5.0)-乙腈(95∶5)为流动相,流速为lmL/min,检测波长220nm,柱温30℃。样品经乙腈提取、乙酸锌沉淀蛋白,HPLC-PDA检测。舒巴坦浓度在10~200μg/mL范围内,线性良好(R2=0.9998),添加回收率为98.82%~101.42%,检出限为0.25mg/kg,定量限为0.75mg/kg。该方法操作简单,结果准确、可靠,适用于原料乳中舒巴坦的快速检测。

关 键 词:舒巴坦  高效液相色谱-二极管阵列检测法  含量测定  原料乳

Determination of sulbactam in raw milk by the high-performance liquid chromatography-photodiode array detection
LIU Shan-shan,SHAN Yi,MAN Chao-xin,XIE Kun-hao,LU Yan,HU Hui-zhi,YAN Tian-wen,JIANG Yu-jun.Determination of sulbactam in raw milk by the high-performance liquid chromatography-photodiode array detection[J].Science and Technology of Food Industry,2012,33(16):64-66.
Authors:LIU Shan-shan  SHAN Yi  MAN Chao-xin  XIE Kun-hao  LU Yan  HU Hui-zhi  YAN Tian-wen  JIANG Yu-jun
Affiliation:1,2,* (1.Key Laboratory of Dairy Science,Ministry of Education,Department of Food Science, Northeast Agricultural University,Harbin 150030,China; 2.National Research Center of Dairy Engineering and Technology,Northeast Agricultural University, Harbin 150086,China)
Abstract:To develop a method for the determination of sulbactam in raw milk using high performance liquid chromatography-photodiode array detector(HPLC-PDA). C18 column was used,the mobile phase consisted of 5.44g/L potassium dihydrogen phosphate solution(pH5.0)-acetonitrile(95∶5) at the flow rate of 1mL/min,the detection wavelength was 220nm.The column temperature was 30℃. Acetonitrile was used for extraction,zinc acetate was used for protein precipitation,the filtered fluid was determined by high performance liquid chromatography-photodiode array detector. The linear calibration curve was obtained in the concentration range of 1~200μg/mL(R2=0.9998) with the lower limit of detection of 0.25mg/kg and lower limit quantification of 0.75mg/kg. The average recovery of sulbactam was 98.82%~101.42%. The method was simple,accurate,reliable and could be used for rapid determination of sulbactam in raw milk.
Keywords:sulbactam  high-performance liquid chromatography-photodiode array(HPLC-PDA) detection  content measured  raw milk
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号