首页 | 本学科首页   官方微博 | 高级检索  
     

基于电感耦合等离子体质谱技术的乳制品中 多种元素的半定量分析方法
引用本文:于 趁,艾连峰,马育松,姚春毅,贾海涛,剧京亚,张云鹏,侯兰静.基于电感耦合等离子体质谱技术的乳制品中 多种元素的半定量分析方法[J].食品安全质量检测技术,2016,7(2):755-761.
作者姓名:于 趁  艾连峰  马育松  姚春毅  贾海涛  剧京亚  张云鹏  侯兰静
作者单位:河北出入境检验检疫局,河北出入境检验检疫局,河北出入境检验检疫局,河北出入境检验检疫局,河北出入境检验检疫局,河北出入境检验检疫局,河北出入境检验检疫局,河北出入境检验检疫局
基金项目:国家质检总局科技计划项目(2013IK154)
摘    要:目的采用电感耦合等离子体质谱法(inductively coupled plasma mass spectrometry,ICP-MS)建立乳制品元素分析的He碰撞反应池模式下半定量检测方法。方法称取0.40~0.50 g样品,加入5 m L硝酸和1 m L双氧水消解完全后,碰撞池反应-电感耦合等离子体质谱法半定量测定。结果通过对样品加标回收及对GSB-8乳粉标准物质的半定量分析,结果显示,该方法能够有效消除干扰,实现对Pb、Cd、Hg、As、Cr、Cu、Zn、Ca等72种元素一次性快速测定,测定结果偏差为(-19.6%)~(+4.9%),实际样品回收率为80.4%~104.9%。结论该方法能快速确定样品中存在的元素及浓度范围,可以应用于奶制品元素含量扫描分析,为快速分析评价乳制品中矿物元素提供科学依据。

关 键 词:半定量分析    多元素    乳制品    碰撞池反应-电感耦合等离子质谱法
收稿时间:2015/11/24 0:00:00
修稿时间:2016/1/31 0:00:00

Determination of multi elements in dairy products by semi quantitative mi-crowave digestion reaction collision cell inductively coupled plasma mass spectrometry
YU Chen,AI Lian-Feng,MA Yu-Song,YAO Chun-Yi,JIA Hai-Tao,JU Jing-Y,ZHANG Yun-Peng and HOU Lan-Jing.Determination of multi elements in dairy products by semi quantitative mi-crowave digestion reaction collision cell inductively coupled plasma mass spectrometry[J].Food Safety and Quality Detection Technology,2016,7(2):755-761.
Authors:YU Chen  AI Lian-Feng  MA Yu-Song  YAO Chun-Yi  JIA Hai-Tao  JU Jing-Y  ZHANG Yun-Peng and HOU Lan-Jing
Affiliation:Hebei Entry-Exit Inspection and Quarantine Bureau,Hebei Entry-exit Inspection and Quarantine Bureau,Hebei Entry-exit Inspection and Quarantine Bureau,Hebei Entry-exit Inspection and Quarantine Bureau,Hebei Entry-exit Inspection and Quarantine Bureau,Hebei Entry-exit Inspection and Quarantine Bureau,Hebei Entry-exit Inspection and Quarantine Bureau and Hebei Entry-exit Inspection and Quarantine Bureau
Abstract:Objective To establish a semi-quantitative detection method in collision reaction pool for the element analysis in dairy products by inductively coupled plasma mass spectrometry (ICP-MS). Methods With adding 5 mL nitric acid and 1 mL hydrogen peroxide, 0.40~0.50 g sample was digested, and then it was determined by semi quantitative microwave digestion reaction collision cell inductively coupled plasma mass spectrometry. Results The sample recovery and semi-quantitative analysis of GSB-8 milk standard reference material showed that this method could effectively eliminate the interference. The implementation of Pb, Cd, Hg, As, Cr, Cu, Zn, Ca and other 64 elements could be simultaneously rapidly determined, the result deviation was in range of (-19.6%)~(+4.9%), and the recoveries of actual samples were 80.4%~104.9%.. Conclusion This method can quickly determine the elements and the concentration range in samples, which can be applied to analyze the element content in dairy and provide scientific basis for the rapid analysis and evaluation of dairy elements.
Keywords:semi quantitative analysis  multi elements  dairy products  collision cell reaction-inductively coupled plasma mass spectrometry
本文献已被 CNKI 等数据库收录!
点击此处可从《食品安全质量检测技术》浏览原始摘要信息
点击此处可从《食品安全质量检测技术》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号