首页 | 本学科首页   官方微博 | 高级检索  
     

电感耦合等离子体质谱法(ICP—MS)测定饮用天然矿泉水中硼酸
引用本文:张激光,刘晶晶,孙海玲.电感耦合等离子体质谱法(ICP—MS)测定饮用天然矿泉水中硼酸[J].饮料工业,2010,13(1):40-42.
作者姓名:张激光  刘晶晶  孙海玲
作者单位:国土资源部沈阳矿产资源监督检测中心,辽宁沈阳,110032
摘    要:用等离子体质谱法,采用p(gBe)=25ng/ml的2%HNO3溶液作为内标溶液在线加入,直接测定饮用天然矿泉水中的硼酸。方法检出限为0.026μg/L,相对标准偏差(RSD,n=12)为8.52%。该方法简单,快速,准确,适用于饮用天然矿泉水中硼酸的测定。

关 键 词:等离子体质谱法  饮用天然矿泉水  硼酸

Determination of boric acid in natural mineral water for drinking by ICP-MS
ZHANG Ji-guang,LIU Jing-jing,SUN Hai-ling.Determination of boric acid in natural mineral water for drinking by ICP-MS[J].Beverage Industry,2010,13(1):40-42.
Authors:ZHANG Ji-guang  LIU Jing-jing  SUN Hai-ling
Affiliation:ZHANG Ji-guang,LIU Jing-jing,SUN Hai-ling (Shenyang Mineral Resources Supervision , Test Center of the Ministry of L, , Resources,Shenyng 110032,Liaoning,China)
Abstract:Boric acid in natural mineral water for drinking was determined directly by ICP-MS, with 2% HNO3 of p (gBe) = 25 ng/ml added on-line as the internal standard solution. The detection limit was 0.026μg/L, and the relative standard deviation (RSD, n= 12) was 8.52%. Being simple, rapid and accurate, the method is suitable for the determination of boric acid in natural mineral water for drinking.
Keywords:ICP-MS  natural mineral water for drinking  boric acid  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号