水体痕量铝快速自动检测方法研究
引用本文:龚文婷,赵冬兰,郜子蕙,余维滨,刘升,郜洪文.水体痕量铝快速自动检测方法研究[J].分析仪器,2021(1):75-81.
作者姓名:龚文婷  赵冬兰  郜子蕙  余维滨  刘升  郜洪文
作者单位:同济大学 环境科学与工程学院,上海 200092;辽宁省有色地质一○五队有限责任公司 ,葫芦岛 125000;上海绿帝环保科技有限公司,上海 200082;淮北师范大学计算机学院 ,淮北 235000
基金项目:国家自然科学基金(21577098)。
摘    要:在氯代十六烷基吡啶(CPC)存在下,铝离子与依来铬菁R(ECR)反应生成蓝色络合物,利用分光光度法研究了配位反应条件:pH 5.75乙酸-乙酸钠缓冲溶液、0.2mL 0.800g·L-1 ECR和0.2mL 1.25g·L-1 CPC,反应10min。基于此优化条件,设计了由进样系统、控制与测量系统组成的自动检测工作程序,建立了铝自动检测方法,并制备了基于室外快速检测使用的铝检测剂Ⅰ、Ⅱ。通过对铝标准溶液、实际水样的测量,自动检测方法与ICP-AES法测定结果一致,其LOD=0.004mg·L-1 Al,RSD 0.5%~1.2%,铝加标回收率93%~102%。同时,稳定性实验表明,铝检测剂Ⅰ、Ⅱ在室温条件下至少稳定半年。该自动检测法具有灵敏度和准确度高、实时动态测量、操作简单等特点,将为水环境移动式自动检测仪的研制提供重要方法和技术。

关 键 词:铝离子  检测剂  分光光度法  自动检测方法

Rapid and automatic determination of trace amounts of aluminum in water
Gong Wenting,Zhao Donglan,Gao Zihui,Yu Weibin,Liu Sheng,Gao Hongwen.Rapid and automatic determination of trace amounts of aluminum in water[J].Analytical Instrumentation,2021(1):75-81.
Authors:Gong Wenting  Zhao Donglan  Gao Zihui  Yu Weibin  Liu Sheng  Gao Hongwen
Affiliation:(College of Environment Science and Engineering,Tongji University,Shanghai 200092,China;Liaoning nonferrous Geology Team 105 Co.,Ltd.,Huludao 125000,Liaoning Province,China;Shanghai Lvdi Environmental Technology Co.,Ltd.,Shanghai 200082,China;School of Computer,Huaibei Normal University,Huaibei 235000,Anhui Province,China)
Abstract:In the presence of cetylpyridinium chloride(CPC),aluminum ion reacts with eriochrome cyanine R(ECR)to form a blue complex.The coordination reaction conditions are studied by spectrophotometric method:pH5.75 acetic acid-sodium acetate buffer solution,0.2 mL 0.800 g·L-1 ECR and 0.2 mL 1.25 g·L-1 CPC,react for 10 minutes.Based on the optimized conditions,an automatic detection program including sampling system,control and measurement system is designed,an automatic detection method for aluminum is established,and the aluminum detection agents I and II for outdoor rapid detection are prepared.The test results of automatic detection method are consistent with those of ICP-AES,LOD=0.004 mg·L-1 Al,RSD is in the range of 0.5%-1.2%,and the recovery rate of aluminum is in the range of 93%-102%.The stability experiment results show that the aluminum detection agents I and II are stable for at least half a year at room temperature.This automatic detection method has the advantages of high sensitivity and accuracy,real-time dynamic measurement,and simple operation.
Keywords:Aluminum ion  Detection agent  Spectrophotometric method  Automatic detection method