摘    要:建立了高效液相色谱-串联质谱法测定猪肉中9种氨基糖苷类药物(壮观霉素、潮霉素B、双氢链霉素、链霉素、阿米卡星、卡那霉素、安普霉素、妥布霉素、庆大霉素)残留量。待测样品中的氨基糖苷类药物经磷酸盐缓冲溶液提取,调节pH值后,经SupelMIP~ SPE-Aminoglycosides分子印迹固相萃取柱净化、浓缩、定容,然后采用Obelisc R高效液相色谱柱分离,以串联质谱法正离子模式检测。该方法在20~1 000μg/L范围内线性关系良好。在线性范围内,分别进行高、中、低3个浓度的添加实验,样品的回收率在76.9%~89.4%之间,相对标准偏差在3.56%~11.4%之间。该方法简便、快速、准确,可以满足猪肉中氨基糖苷类药物残留的测定需求。

关 键 词:氨基糖苷类药物  亲水性色谱柱  分子印迹固相萃取  高效液相色谱-串联质谱(HPLC-MS/MS)  

Determination of Aminoglycosides Residue in Pork by Hydrophilic Obelisc R Column-HPLC-MS/MS
ZHAO Feng-juan,FANG En-hua,HAN Rui-yang,PENG Yi-hou,LUO Yao,XIONG Bei-bei,CAI Yi-na,LI Li-su.Determination of Aminoglycosides Residue in Pork by Hydrophilic Obelisc R Column-HPLC-MS/MS[J].Journal of Chinese Mass Spectrometry Society,2018,39(1):76-84.
Authors:ZHAO Feng-juan  FANG En-hua  HAN Rui-yang  PENG Yi-hou  LUO Yao  XIONG Bei-bei  CAI Yi-na  LI Li-su
Affiliation:1.Food Inspection and Quarantine Center, Shenzhen Entry-Exit Inspection and Quarantine Bureau, Shenzhen Key Laboratory of Detection Technology R&D on Food Safety, Shenzhen 518045, China; 2.Xiamen Entry-Exit Inspection and Quarantine Technology Center, Xiamen 361026, China
Abstract:The molecular structure and physicochemical property of common aminoglycosides (AGs) antibiotics were systematically analyzed and the residue of animal origin foodstuffs as well as the corresponding damage on human body with long-term intake were introduced. Concrete ideas of the study were raised based on the analysis of present analytical approaches and the discussion of existing defects. An HPLC-MS/MS analytical method was developed for the simultaneous determination of aminoglycosides (spectinomycin, hygromycin B, dihydrostrepmycin, streptomycin, amkacin, kanamycin, apramycin, tobramycin, gentamicin) with a new hydrophilic HPLC column. The residues of aminoglycosides in the test samples were extracted with phosphate buffer solution. After ajusting pH values, the samples were cleaned up with SupelMIP® SPE column, concentrated and reconstituted, the residues were separated by Obelisc R HPLC column (2.1 mm×150 mm×5 μm, 100 ) by gradient elution with acetonitrile-water (1% formic acid) as mobile phase, and detected by liquid chromatography-mass spectrometry under multiple reaction monitoring (MRM) mode via positive-ion mode. All the analytes were calibrated by the external method. The matrix effects were evaluated by comparing solvent prepared standards to matrix-matched standards. The effects of different solid-phase extraction (SPE) columns were optimized. The use of the SupelMIP SPE-Aminoglycoside cartridge kept the analytes bound to the sorbent while a series of aggressive washes were applied to the sorbent to eliminate matrix interferences. The Obelisc R column has reverse phase property and could be applied to conventional reverse phase conditions. It had high density of positive and negative ions on a stationary phase surface, its adsorption capacity in polar compounds could be greatly improved compared with the traditional revers-phase chromatographic column. This allows retaining polar compounds without using ion-pairing reagents. The content of acetonitrile and pH of buffer were adjusted so that the 9 AGs were better retained and separated. The results showed that all the aminoglycosides had good linearity in the range of 20-1 000 μg/L, and the correlation coefficients (R2) were greater than 0.99. The limits of quantification (LOQs) of the nine targets are 50 μg/kg. The average recoveries range from 76.9% to 89.4% for the 9 targets at three spiked levels in pork, and the relative standard deviations were 3.56%-11.4%. This method is proved to be highly sensitive, accurate and reproducible, and it is suitable for the detection of aminoglycosides in pork.
Keywords:aminoglycosides  hydrophilic chromatographic column  molecular imprinting solid phase extraction  high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS)  