COMPARISON AND ANALYSIS OF THREE DIFFERENT NON-CONTACTING FLAME TEMPERATURE FIELD MEASUREMENTS
作者姓名:Feng Zhimin  Wang Ying  Hu Haigang  Lang Haoxiang
作者单位:Feng Zhimin Wang Ying Hu Haigang Lang Haoxiang Department of Marine Engineering,Ningbo University,Ningbo 315211,China
基金项目:This project is supported by National Natural Science Foundation of China(No.59776005),Provincial Science Foundation of Education Department of Zhejiang, China (No.20000002)
摘    要:A much better substitutional means is discussed to calculate the flame temperature field with the application of digital image processing technology. Three non-contacting temperature measurements are used and compared. Such as the traditional two-color temperature measurement,the CCD filtering two-color temperature measurement and the monochromatic temperature measurement. It is indicated that the CCD two-color temperature measurement is not a fully correct means because of its poor theoretical basis. The monochromatic temperature measurement acquires a relatively ideal temperature field distribution in spite of needing a reference temperature. It should be noted that the Abel transformation applied in the plasma diagnosis is for the first time introduced to solve the problem of three-dimensional flame brightness piling.

关 键 词:火焰温度检测  非接触式  测温  温度场  CCD  比较分析

COMPARISON AND ANALYSIS OF THREE DIFFERENT NON-CONTACTING FLAME TEMPERATURE FIELD MEASUREMENTS
Feng Zhimin,Wang Ying,Hu Haigang,Lang Haoxiang.COMPARISON AND ANALYSIS OF THREE DIFFERENT NON-CONTACTING FLAME TEMPERATURE FIELD MEASUREMENTS[J].Chinese Journal of Mechanical Engineering,2003,16(2):221-224.
Authors:FengZhimin WangYing HuHaigang LangHaoxiang
Affiliation:DepartmentofMarinaEngineering,NingboUniversity,Ningbo315211,China
Abstract:A much better substitutional means is discussed to calculate the flame temperature field with the application of digital image processing technology. Three non-contacting temperature measurements are used and compared. Such as the traditional two-color temperature measurement,the CCD filtering two-color temperature measurement and the monochromatic temperature measurement. It is indicated that the CCD two-color temperature measurement is not a fully correct means because of its poor theoretical basis. The monochromatic temperature measurement acquires a relatively ideal temperature field distribution in spite of needing a reference temperature. It should be noted that the Abel transformation applied in the plasma diagnosis is for the first time introduced to solve the problem of three-dimensional flame brightness piling.
Keywords:Flame Temperature field Image processing