首页 | 本学科首页   官方微博 | 高级检索  
     

基于虚拟立体视觉的气液两相流三维测量系统的标定
引用本文:薛婷,曹兆峰,金俞鑫.基于虚拟立体视觉的气液两相流三维测量系统的标定[J].光学精密工程,2012,20(1):124-130.
作者姓名:薛婷  曹兆峰  金俞鑫
作者单位:天津大学电气与自动化工程学院,天津300072;天津市过程检测与控制重点实验室,天津300072
基金项目:国家自然科学基金资助项目(No.60902084,61172120);教育部博士点新教师基金资助项目(No.200800561059);精密测试技术及仪器国家重点实验室开放基金资助项目 (No.PIL0902);天津大学自主创新基金资助项目
摘    要:研究了基于虚拟立体视觉的气液两相流三维测量系统的标定技术。首先,基于单台高速摄像机和两组反射镜组构建虚拟立体视觉测量系统,建立高速摄像机透视投影变换模型以及虚拟立体视觉三维测量模型,对虚拟立体视觉系统中摄像机及虚拟立体视觉传感器进行标定。用靶标基准球模拟气泡在水中的分布,以其空间距离作为测量评价指标,比较了不同标定方法对三维重建精度的影响。实验结果表明,将标定参照物置于水箱内,并且分别对左、右虚拟摄像机及传感器进行标定,三维重建精度最高,测量空间距离绝对误差优于0.13 mm,相对误差优于0.49%。实验认为,对基于虚拟立体视觉的气液两相流三维测量系统进行标定时,必须充分考虑折光分光光路以及管壁折射对三维重建所带来的影响。

关 键 词:气液两相流  三维测量系统  虚拟立体视觉  标定  误差分析
收稿时间:2011-08-08
修稿时间:2011-09-28

Calibration of three-dimensional measurement system for gas-liquid two phase flow based on virtual stereo vision
XUE Ting , CAO Zhao-feng , JIN Yu-xin.Calibration of three-dimensional measurement system for gas-liquid two phase flow based on virtual stereo vision[J].Optics and Precision Engineering,2012,20(1):124-130.
Authors:XUE Ting  CAO Zhao-feng  JIN Yu-xin
Affiliation:1. College of Electrical Engineering and Automation, Tianjin University, Tianjin 300072, China;; 2. Tianjin Key Laboratory of Process Measurement and Control, Tianjin 300072, China
Abstract:A calibration technique for the three-dimensional measurement system of gas-liquid two phase flow based on a virtual stereo vision was researched. Firstly, a single high-speed camera and two groups of mirrors were used to construct the virtual stereo vision system and to establish a perspective transformation model for the high-speed camera and a virtual stereo vision three-dimensional measurement model. Then, the camera and the virtual stereo vision sensor in the virtual stereo vision system were calibrated. Finally, the distribution of the bubble in the water was simulated by a target standard ball and its space distance was regard as the measurement standards. Furthermore, the impacts of different calibration methods on the accuracy of three-dimensional reconstruction were compared. Experimental results indicate that the accuracy of the three-dimensional reconstruction is the best when the calibration reference is placed in a water tank and the left and right virtual cameras and sensors are calibrated, respectively. The absolute error and the relative error of the measurement distance are better than 0.13 mm and 0.49%, respectively. It suggests that the impact of the light splitting path and tube wall refraction on the calibration accuracy should be taken full account of in the calibration of the gas-liquid two-phase flow three-dimensional measurement system based on the virtual stereo vision system.
Keywords:gas-liquid two phase flow  three-dimensional measurement system  virtual stereo vision  calibration  error analysis
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《光学精密工程》浏览原始摘要信息
点击此处可从《光学精密工程》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号