首页 | 本学科首页   官方微博 | 高级检索  
     

分时偏振光谱测量系统的起偏效应校正
引用本文:张海洋,李颐,颜昌翔,张军强.分时偏振光谱测量系统的起偏效应校正[J].光学精密工程,2017,25(2):325-333.
作者姓名:张海洋  李颐  颜昌翔  张军强
作者单位:1. 中国科学院 长春光学精密机械与物理研究所, 吉林 长春 130033;2. 中国科学院大学, 北京 100049
基金项目:国家863高技术研究发展计划资助项目,国家自然科学基金青年基金资助项目
摘    要:针对实验室偏振光谱测量系统短波红外起偏效应大、测量偏差大的问题,建立了系统目标斯托克斯校正模型,提出了该模型中相关系数的测量方法,从而实现了系统偏振效应的精密校正。首先分析了实验室常用的低成本分时偏振光谱测量系统存在的主要问题及起偏效应的来源。然后根据偏振传输理论,将系统中起偏效应较大的波谱仪等效为检偏系统,建立了目标偏振信息的校正模型,并通过与理想模型的对比验证了模型的正确性。最后针对本测量设备,为提高校正系数的测量精度,在解析法的基础上提出了一种更精确的拟合法。实验结果表明,本方法的校正精度高于0.5%,满足实验室中对目标偏振信息处理的精度要求,对偏振光谱测量系统的研制和标定具有指导意义。

关 键 词:偏振遥感  偏振光谱  起偏效应校正  偏振传输理论  相关系数  ASD光谱仪
收稿时间:2016-06-01

Calibration of polarized effect for time-divided polarization spectral measurement system
ZHANG Hai-yang,LI Yi,YAN Chang-xiang,ZHANG Jun-qiang.Calibration of polarized effect for time-divided polarization spectral measurement system[J].Optics and Precision Engineering,2017,25(2):325-333.
Authors:ZHANG Hai-yang  LI Yi  YAN Chang-xiang  ZHANG Jun-qiang
Affiliation:1. Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China;2. University of Chinese Academy of Sciences, Beijing 100049, China
Abstract:Aiming at the problems of polarizing effect in short wave infrared and measurement deviation in the polarization spectral measurement system built in lab,a system calibration model was established and a method to measure the correction coefficients of the model was proposed,thus the polarizing effect was calibrated precisely.Firstly,the main problem of the regular time-divided polarization spectral measurement system was described and the origin of the polarizing effect was analyzed.An ASD spectrometer which had a serious polarizing effect functioned as an analyzer according to the polarization transmission theory.Thereby a system calibration model was established and verified by comparing with the ideal model widely used.Then,a high precision fitting method of the correction coefficients was proposed for improving the measurement accuracy based on the analytical method.Experimental results indicate that the calibration precision is higher than 0.5 %,which can fully satisfy the requirements of target polarization information processing in laboratory.This method has a great significance for the development and calibration of polarization spectra measurement system.
Keywords:polarization remote sensing  polarization spectra  polarizing effect calibration  polarization transmission theory  correction coefficient  ASD spectrometer
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《光学精密工程》浏览原始摘要信息
点击此处可从《光学精密工程》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号