首页 | 本学科首页   官方微博 | 高级检索  
     

眼轴长度测量方法及进展研究
引用本文:王成,董肖娜,项华中,郑刚,张大伟.眼轴长度测量方法及进展研究[J].光学仪器,2019,41(2):72-79.
作者姓名:王成  董肖娜  项华中  郑刚  张大伟
作者单位:上海理工大学 生物医学光学与视光学研究所,上海 200093;上海理工大学 上海市现代光学系统重点实验室,上海 200093;上海理工大学 教育部光学仪器与系统工程研究中心,上海 200093
基金项目:国家自然科学基金(61378060)
摘    要:为配合临床实现人工晶体屈光度数计算,以及为日常眼病预防提供依据,眼生物参数测量特别是眼轴长度测量逐渐被人们所重视。以眼轴长度为目标,论述了现有的眼轴长度测量方法,包括超声测量方法和光学测量方法。重点概述了光学部分相干原理,低相干原理和光学相干层析(OCT)技术在眼轴长度测量方面的研究进展,分别介绍了各方法及典型仪器的测量原理、测量精度及范围,论述了眼轴长度测量的发展方向。光学测量方法以其无损伤、快速、高精度等优点逐渐替代了超声测量方法,但对于晶体混浊眼还需依靠超声测量方法。

关 键 词:眼轴长度  部分相干  低相干反射  光学相干层析  超声
收稿时间:2018/3/13 0:00:00

Progress and measurement methods of axial eye length
WANG Cheng,DONG Xiaon,XIANG Huazhong,ZHENG Gang and ZHANG Dawei.Progress and measurement methods of axial eye length[J].Optical Instruments,2019,41(2):72-79.
Authors:WANG Cheng  DONG Xiaon  XIANG Huazhong  ZHENG Gang and ZHANG Dawei
Affiliation:Institute of Medical Optics and Optometry, University of Shanghai for Science and Technology,Shanghai 200093, China,Institute of Medical Optics and Optometry, University of Shanghai for Science and Technology,Shanghai 200093, China,Institute of Medical Optics and Optometry, University of Shanghai for Science and Technology,Shanghai 200093, China,Institute of Medical Optics and Optometry, University of Shanghai for Science and Technology,Shanghai 200093, China and Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, Shanghai 200093, China;Engineering Research Center of Optical Instrument and System(MOE), University of Shanghai for Science and Technology, Shanghai 200093, China
Abstract:In order to coordinate with the clinical implementation of intraocular lens diopter calculation, and to provide basis for the prevention of eye diseases, the measurement of ocular biological parameters, especially the axial eye length, has attracted more and more attention. This paper mainly discusses the existing measurement methods of axial eye length, which includes traditional ultrasonic measurement method and optical measurement method. This mainly summarizes progress of the measurements of the axial eye length in the partial coherence interferometry, optical low coherence reflectometry and optical coherence tomography. The measurement principle, measurement precision and range of each method and typical instrument are introduced. The development direction of axial eye length measurement is discussed. The ultrasonic measurement method has been gradually replaced by the optical measurement method with the advantages of no damage, rapid and high precision. However, it is necessary to rely on ultrasonic measurement for eyes which lens is opacity.
Keywords:axial eye length  partial coherence interferometry  optical low coherence reflectometry  optical coherence tomography  ultrasound
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《光学仪器》浏览原始摘要信息
点击此处可从《光学仪器》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号