首页 | 本学科首页   官方微博 | 高级检索  
     

模块化多电平换流器电容用量的标幺化分析与设计方法
引用本文:周月宾,宋强,杨柳,张楠,李政轩,曹琬钰. 模块化多电平换流器电容用量的标幺化分析与设计方法[J]. 电力建设, 2021, 42(11): 1-12. DOI: 10.12204/j.issn.1000-7229.2021.11.001
作者姓名:周月宾  宋强  杨柳  张楠  李政轩  曹琬钰
作者单位:直流输电技术国家重点实验室(南方电网科学研究院),广州市510663;电力系统及大型发电设备安全控制和仿真国家重点实验室(清华大学) ,北京市100084;中国南方电网有限责任公司超高压输电公司检修试验中心,广州市510663
基金项目:国家重点研发计划项目(2016YFB0901005);南方电网公司科技项目(ZBKJXM20180663)
摘    要:子模块电容用量是影响模块化多电平换流器(modular multilevel converter,MMC)体积和成本的关键因素。提出了以单位容量额定储能值作为MMC电容用量的统一的衡量与直接设计指标,建立了直接描述MMC所需额定储能值与电容电压波动率之间关系的标幺化计算模型,使不同额定参数MMC的电容用量的衡量、计算和分析可以得到统一和简化。与以子模块电容值作为分析和设计指标的传统方法相比,MMC额定储能值标幺化计算模型去除了多种参数对计算过程的影响,揭示了基准调制比和输出功率范围是影响MMC额定储能值的关键因素。基于所提出的额定储能值标幺化计算模型,对MMC额定储能设计值随基准调制比和功率输出范围的变化规律进行了详细分析,为MMC电容用量的设计和优化提供了明确的依据。数字仿真和物理试验结果验证了所提方法的正确性。

关 键 词:模块化多电平换流器(MMC)  电容电压波动  电容用量  额定储能值
收稿时间:2021-05-31

Design and Analysis for Energy Storage Requirements of Modular Multilevel Converter Applying Per-unit Model
ZHOU Yuebin,SONG Qiang,YANG Liu,ZHANG Nan,LI Zhengxuan,CAO Wanyu. Design and Analysis for Energy Storage Requirements of Modular Multilevel Converter Applying Per-unit Model[J]. Electric Power Construction, 2021, 42(11): 1-12. DOI: 10.12204/j.issn.1000-7229.2021.11.001
Authors:ZHOU Yuebin  SONG Qiang  YANG Liu  ZHANG Nan  LI Zhengxuan  CAO Wanyu
Affiliation:1. State Key Laboratory of HVDC (Electric Power Research Institute, CSG), Guangzhou 510663, China2. State Key Laboratory of Power System and Generation Equipment (Tsinghua University), Beijing 100084, China3. Maintenance and Test Center of Extra High Voltage Power Transmission Co., China Southern Power Grid, Guangzhou 510663, China
Abstract:The submodule capacitance is a key factor affecting the volume and cost of modular multilevel converter (MMC). The normalized value of the energy stored in an MMC with respect to the rated capacity is taken as the unified index for evaluating the capacitance usage of an MMC. A per-unit model that describes the relationship between energy storage requirement (ESR) value and the fluctuation rate of capacitor voltage is established. Thereby, the evaluation, calculation and analysis of the ESR values of MMCs with different rated parameters can be unified and simplified. Compared with the conventional methods of taking the capacitance value as the design and analysis index, the per-unit model for calculating the ESR value eliminates the influence of various parameters on the calculation results. It is revealed that the ESR value is mainly affected by the base modulation index and the per-unit active and reactive power output. Based on the proposed model, the variation of the ESR value with the modulation index and the power output range is analyzed in detail, which provides a clear and accurate basis for the design and optimization of MMC capacitance usage. The results of digital simulation and experimental results verify the proposed methods.
Keywords:modular multilevel converter(MMC)   capacitor voltage fluctuation   capacitance usage   rated energy-storage requirement
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《电力建设》浏览原始摘要信息
点击此处可从《电力建设》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号