首页 | 本学科首页   官方微博 | 高级检索  
     

密相气力输送中气固两相流动特性多源信息分析
引用本文:付飞飞,许传龙,王式民. 密相气力输送中气固两相流动特性多源信息分析[J]. 化工学报, 2012, 63(10): 3070-3079. DOI: 10.3969/j.issn.0438-1157.2012.10.010
作者姓名:付飞飞  许传龙  王式民
作者单位:东南大学能源与环境学院, 能源热转换及其过程测控教育部重点实验室(东南大学), 江苏 南京 210096
基金项目:国家自然科学基金项目(50836003,50906012);国家重点基础研究发展计划项目(2010CB227002)~~
摘    要:在加压密相气力输送煤粉实验装置上,结合静电、压力传感器与电容层析成像系统(ECT)3种方法,利用统计学和分形方法研究了不同操作条件(总输送压差、输送载气和煤粉含水率等)下密相气固两相流动力学行为。结果表明:输送载气为CO2时,颗粒相微观运动剧烈程度随总输送压差(0.3~1 MPa)的增大而增大,气流和颗粒相之间的相互作用在总输送压差0.75 MPa下最强烈,但煤粉宏观整体的流动保持稳定;煤粉含水率增加对宏观流动稳定性没有影响,但水分增加使颗粒相的微观运动剧烈性减小;载气为N2时,管道截面煤粉的平均浓度及分布变化明显,宏观流动状态不稳定,但颗粒相的微观运动剧烈程度与载气为CO2时的变化规律一致。

关 键 词:静电传感器  电容层析成像  气固两相流  分形  
收稿时间:2012-03-08
修稿时间:2012-05-30

Multi-sensors integration for flow characterization of dense phase pneumatic conveying of coal powder
FU Feifei , XU Chuanlong , WANG Shimin. Multi-sensors integration for flow characterization of dense phase pneumatic conveying of coal powder[J]. Journal of Chemical Industry and Engineering(China), 2012, 63(10): 3070-3079. DOI: 10.3969/j.issn.0438-1157.2012.10.010
Authors:FU Feifei    XU Chuanlong    WANG Shimin
Affiliation:Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education, School of Energy and Environment, Southeast University, Nanjing 210096, Jiangsu, China
Abstract:Multi-sensor integration including electrostatic sensor,pressure sensor and capacitance tomography system(ECT)were used to investigate the flow behavior of dense phase pneumatic conveying of coal powder under various operating conditions(transportation pressure difference,carrier gas and moisture content).Statistics and fractal method were applied to extracting the Hurst of electrostatic fluctuation signal and the variance of differential pressure signal.Experimental results showed that when CO2 was used as carrier gas,the complexity of micro-movement of individual particle increased with increasing total transportation pressure difference and the interaction between gas and particles was more intensified under pressure difference of 0.75 MPa.However,the macro-motion state of the coal particles kept stable.The increase of coal moisture content resulted in higher complexity of micro-motion of individual particle,and yet had no influence on the stability of macro-motion state of the whole coal particles.When N2 was used as carrier gas,coal average concentration over the cross section of the pipeline fluctuated obviously and the macro-motion state of the whole coal particles was unstable.But the micro- motion of individual coal particle was similar to that with carrier gas of CO2.
Keywords:electrostatic sensor  electrostatic capacitance tomography  gas-solids two-phase flow  fractal method
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《化工学报》浏览原始摘要信息
点击此处可从《化工学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号